E1FU | Ex e, Ex d, Ex nR, Ex ta | Explosive Atmosphere Cable Gland For all types of Armoured cables

Globally Approved, Explosive Atmosphere Cable Gland

• Metal-to-metal armour clamping
• Direct & remote installation
• Displacement type flameproof inner seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Designed to prevent Coldflow, see CMP Technical Document TS001 (available upon request)
• -60?C to +130?C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 2 ABCD
• Globally marked, IECEx, ATEX & cCSAus
• EMC tested

Note: † Grooved Cone (X) is predominantly used for Wire Braid (e.g. GSWB, TCWB), Steel Tape Armour (STA, DSTA) and Aluminium Strip Armour (ASA) but is also suitable for Single Wire Armour (SWA), Aluminium Wire Armour (AWA) and Pliable Wire Armour (PWA) if the range is outside that of the Stepped Cone (W).

Note: Grooved Cone (X) dimensions shown in the Cable Gland Selection Table below are for a double wire strand of braid armour cables. Tapes can also be doubled over. For cables that have only a
single layer of armour such as SWA the clamping range should be used as shown in the table below.

Stepped (W) Cone is suitable for Single Wire Armour (SWA), or Aluminium Wire Armour (AWA) cables.

For under / oversized armour wires click here

Design SpecificationBS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications *Impact = Level 8, Retention = Class D
Enclosure ProtectionIK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications *Category B (Category A when used with braid, tape or pliable wire armour cables)
ATEX CertificateSIRA13ATEX1071X, SIRA13ATEX4077X
Code of Protection II 2G, II 1D, Ex d IIC Gb, Ex e IIC Gb, Ex ta IIIC Da
II 3G Ex nR IIC Gc, IM2 Ex d I Mb, Ex e I Mb
Compliance StandardsEN 60079-0,1,7,15,31
IECEx CertificateIECEx SIR 13.0026X, IECEx SIM 14.0007X
Code of ProtectionEx d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex d I Mb, Ex e I Mb
Compliance StandardsIEC 60079-0,1,7,15,31
cCSAus Certificate1310517
Code of ProtectionEx d IIC; Ex e II; Ex nR II; Class I, Div 2, Groups A,B,C,D, Class II, Div 2 Groups E,F,G, Class III;
Encl Type T4X Class I, Zone 1, AEx e II / AEx nR II
Compliance StandardsCAN/CSA-C22.2 No 0,18,25,30,174,94, CAN/CSA-E60079-0,1,7,15
ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079-0,1,7,15
EAC CertificateTC RU C-GB.AA87.B.00487
KCC Certificate14-GA4BO-0257X
NEPSI CertificateGYJ13.1140X , GYJ13.1282X
CCOE / PESO (India) CertificateP333688
INMETRO ApprovalTÜV 12.0618X
RETIE Approval03866
Marine ApprovalsLRS: 01/00173, DNV: TAE00000Y, ABS: 14-LD234401A-4-PDA, BV: 43180/A1BV
Ingress Protection Rating **IP66 as standard (IP67, IP68 available upon request)
Deluge Protection ComplianceDTS01:91 option available on request (white ferrule for identification purposes)
Cable Gland MaterialBrass, Electroless Nickel Plated Brass, Aluminium
Seal MaterialCMP SOLO LSF Halogen Free Thermoset Elastomer
Cable TypeSingle Wire Armour (SWA), Aluminium Wire Armour (AWA), Steel Tape Armour (STA), Wire
Braid Armour (e.g. SWB), Aluminium Strip Armour (ASA), Pliable Wire Armour (PWA),
Screened Flexible (EMC) Wire Braid (e.g. CY / SY), Armoured & Jacketed
Armour ClampingReversible Armour Cone & AnyWay Universal Clamping Ring
Sealing TechniqueCMP Inner Displacement Seal & Unique CMP ‘LRS’ ™ Outer Load Retention Seal
Sealing Area(s)Cable Inner Bedding & Outer Cable Sheath
Optional AccessoriesLocknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation ToolsSpanners, Armour Former Tool

Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
*** IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request

Certificates

Click here to view Certificates

Product Selection Table

Click here to view Technical Illustration

Technical Illustration

Click here to view how to order

Cable Gland SizeAvailable Entry Threads ?C? (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
?A?
Overall
Cable
Diameter
?B?
Armour RangeAcross
Flats
?D?
Across
Corners
?D?
Protrusion
Length ?F?
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Ozs)
StandardOptionGrooved
Cone (X)
Stepped Cone (W)
MetricThread Length (Metric) ?E?NPTThread Length
(NPT) ?E?
NPTMinMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M200.59½?0.78¾"0.120.340.240.520.010.040.030.050.941.042.8520S16E1FU1RAPVC045.64
20SM200.59½?0.78¾"0.240.460.370.630.010.040.030.050.941.042.7620SE1FU1RAPVC045.29
20M200.59½?0.78¾"0.260.550.490.820.020.040.030.051.201.322.8720E1FU1RAPVC067.41
25SM250.59¾?0.801"0.440.780.550.870.020.050.050.061.481.633.5025SE1FU1RAPVC0911.64
25M250.59¾?0.801"0.440.780.721.030.020.050.050.061.481.633.5025E1FU1RAPVC0911.64
32M320.591?0.981 ¼"0.671.030.931.330.020.050.060.081.811.993.3932E1FU1RAPVC1115.17
40M400.591 ¼?1.011 ½"0.871.261.101.590.020.060.060.082.172.383.5440E1FU1RAPVC1521.87
50SM500.591 ½?1.032"1.161.501.391.840.020.060.080.102.362.603.5850SE1FU1RAPVC1826.46
50M500.592?1.062 ½"1.401.731.592.090.020.060.080.102.763.043.7450E1FU1RAPVC2133.51
63SM630.592?1.062 ½"1.581.961.802.340.020.060.080.102.953.254.0263SE1FU1RAPVC2347.27
63M630.592 ½?1.573"1.862.202.152.590.020.060.080.103.153.464.0963E1FU1RAPVC2547.27
75SM750.592 ½?1.573"2.082.442.322.830.020.060.080.103.543.904.5375SE1FU1RAPVC2874.43
75M750.593?1.633 ½"2.332.672.633.090.020.060.100.123.944.334.6175E1FU1RAPVC3085.36
90M900.943 ½?1.694"2.623.093.003.560.030.060.120.164.504.945.7990E1FU1RAPVC32148.50
100M1000.943 ½?1.694"2.993.583.393.990.030.060.120.164.845.335.51100E1FU1RALSF33156.97
115M1150.944"1.735"3.393.854.004.340.030.060.120.165.255.786.38115E1FU1RALSF34218.35
130M1300.945"1.84-3.824.524.344.850.030.060.120.166.006.606.85130E1FU1RALSF35294.19
Dimensions displayed in inches unless otherwise stated
Cable Gland SizeAvailable Entry Threads ?C? (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
?A?
Overall
Cable
Diameter
?B?
Armour RangeAcross
Flats
?D?
Across
Corners
?D?
Protrusion
Length ?F?
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Kgs)
StandardOptionGrooved
Cone (X)
Stepped Cone (W)
MetricThread Length (Metric) ?E?NPTThread Length
(NPT) ?E?
NPTMinMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M2015.0½?19.9¾"3.18.66.113.10.31.00.81.2524.026.472.520S16E1FU1RAPVC040.16
20SM2015.0½?19.9¾"6.111.69.515.90.31.00.81.2524.026.470.020SE1FU1RAPVC040.15
20M2015.0½?19.9¾"6.513.912.520.90.41.00.81.2530.533.673.020E1FU1RAPVC060.21
25SM2515.0¾?20.21"11.119.914.022.00.41.21.251.637.541.389.025SE1FU1RAPVC090.33
25M2515.0¾?20.21"11.119.918.226.20.41.21.251.637.541.389.025E1FU1RAPVC090.33
32M3215.01?25.01 ¼"17.026.223.733.90.41.21.62.046.050.686.032E1FU1RAPVC110.43
40M4015.01 ¼?25.61 ½"22.032.127.940.40.41.61.62.055.060.590.040E1FU1RAPVC150.62
50SM5015.01 ½?26.12"29.538.135.246.70.41.62.02.560.066.091.050SE1FU1RAPVC180.75
50M5015.02?26.92 ½"35.644.040.453.00.61.62.02.570.177.195.050E1FU1RAPVC210.95
63SM6315.02?26.92 ½"40.149.945.659.40.61.62.02.575.082.5102.063SE1FU1RAPVC231.34
63M6315.02 ½?39.93"47.255.954.665.80.61.62.02.580.088.0104.063E1FU1RAPVC251.34
75SM7515.02 ½?39.93"52.861.959.072.00.61.62.02.590.099.0115.075SE1FU1RAPVC282.11
75M7515.03?41.53 ½"59.167.966.778.40.61.62.53.0100.0110.0117.075E1FU1RAPVC302.42
90M9024.03 ½?42.84"66.678.676.290.30.81.63.154.0114.3125.4147.090E1FU1RAPVC324.21
100M10024.03 ½?42.84"76.090.986.1101.40.81.63.154.0123.0135.3140.0100E1FU1RALSF334.45
115M11524.04"44.05"86.097.9101.5110.20.81.63.154.0133.4146.7162.0115E1FU1RALSF346.19
130M13024.05"46.8-97.0114.9110.2123.20.81.63.154.0152.4167.6174.0130E1FU1RALSF358.34
Dimensions displayed in millimeters unless otherwise stated