PX2KREX | Ex eb, Ex db, Ex nR, Ex ta | Explosive Atmosphere Barrier Cable Gland For all types of Armoured Cables

Globally Approved, Explosive Atmosphere RapidEx Barrier Cable Gland

• RapidEx liquid pour sealing system
– Enhances reliability, reduces risk
– Reduces man hours
– Reduces cost
• Metal-to-metal armour clamping
• Direct & remote installation
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +85°C
• Globally marked, IECEx, ATEX & cCSAus
• Superior EMC tested
• Once any cable inner sheath/bedding has been removed, the RapidEx liquid resin barrier seals directly around the internal cable cores, completely eliminating any risk of coldflow on all cable types

For under / oversized armour wires click here

Patent granted: ES 2287986, NO 2287986, TR 2287986, AU 2010284848, AU 2014274614, GB 2485114, SG 178839, US 8872027, US 9484133, US 9774178, MY 153846, US 10193321, US1034078

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications* Impact = Level 8, Retention = Class D
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications * Category B (Category A when used with braid, tape or pliable wire armour cables)
ATEX Certificate CML 18ATEX1325X, CML 18ATEX4317X
UKEX Certificate CML 21UKEX1214X, CML 21UKEX4215X
Code of Protection II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da
II 3G Ex nR IIC Gc, IM2 Ex db I Mb, Ex eb I Mb

Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
**** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
***Where the cable is permitted by code (NEC and/or CEC)
****IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request


Jump to technical illustration   

Certificates

Click here to view Certificates

Product Selection Table

Click here to view how to order

Cable Gland SizeAvailable Entry Threads "C" (Alternate Metric Thread Lengths Available)Number of CoresDiameter Over Conductors "A"Cable Bedding Diameter "G"Overall Cable Diameter "B"Armour RangeAcross
Flats
"D"
Across
Corners
"D"
Protrusion
Length "F"
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Ozs)
StandardOptionGrooved Cone (X)Stepped Cone (W)
MetricThread Length (Metric) "E"NPTThread Length (NPT) "E"NPTMaxMaxMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M200.59½"0.78¾"210.460.460.240.520.010.040.030.051.201.322.4420S16PX2KREX1RAPVC068.47
20SM200.59½"0.78¾"210.460.460.370.630.010.040.030.051.201.322.4420SPX2KREX1RAPVC068.11
20M200.59½"0.78¾"210.500.510.490.820.020.040.030.051.201.322.4820PX2KREX1RAPVC068.47
25SM250.59¾"0.801"300.690.700.550.870.020.050.050.061.481.632.7425SPX2KREX1RAPVC0913.05
25M250.59¾"0.801"300.690.700.721.030.020.050.050.061.481.632.7425PX2KREX1RAPVC0913.05
32M320.591"0.981 ¼"500.930.940.931.330.020.050.060.081.811.992.9532PX2KREX1RAPVC1120.11
40M400.591 ¼"1.011 ½"591.181.191.101.590.020.060.060.082.172.382.9540PX2KREX1RAPVC1528.22
50SM500.591 ½"1.032"891.441.451.391.840.020.060.080.102.362.603.0350SPX2KREX1RAPVC1831.75
50M500.592"1.062 ½"1151.611.631.592.090.020.060.080.102.763.033.0350PX2KREX1RAPVC2141.98
63SM630.592"1.062 ½"1151.891.881.802.340.020.060.080.102.953.253.1463SPX2KREX1RAPVC2349.03
63M630.592 ½"1.573"1152.112.132.152.590.020.060.080.103.153.463.1663PX2KREX1RAPVC2549.74
75SM750.592 ½"1.573"1402.362.372.322.830.020.060.080.103.543.903.4275SPX2KREX1RAPVC2873.72
75M750.593"1.633 ½"1402.532.532.633.090.020.060.100.123.944.333.4875PX2KREX1RAPVC3089.60
90M900.793 ½"1.694"2002.962.983.003.560.030.060.120.164.534.984.0290PX2KREX1RAPVC32130.87
100M1000.793 ½"1.694"2003.373.383.393.990.030.060.120.165.005.504.49100PX2KREX1RALSF33169.67
Dimensions are displayed in inches unless otherwise stated
Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Number of CoresDiameter Over Conductors "A"Cable Bedding Diameter "G"Overall Cable Diameter 'B'Armour RangeAcross
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Kgs)
StandardOptionGrooved Cone (X)Stepped Cone (W)
MetricThread Length (Metric) 'E'NPTThread Length (NPT) 'E'NPTMaxMaxMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M2015.0½"19.9¾"2111.711.76.113.10.31.00.81.2530.533.662.020S16PX2KREX1RAPVC060.24
20SM2015.0½"19.9¾"2111.711.79.515.90.31.00.81.2530.533.662.020SPX2KREX1RAPVC060.23
20M2015.0½"19.9¾"2112.612.912.520.90.41.00.81.2530.533.663.020PX2KREX1RAPVC060.24
25SM2515.0¾"20.21"3017.517.914.022.00.41.21.251.637.541.369.525SPX2KREX1RAPVC090.37
25M2515.0¾"20.21"3017.517.918.226.20.41.21.251.637.541.369.525PX2KREX1RAPVC090.37
32M3215.01"25.01 ¼"5023.623.923.733.90.41.21.62.046.050.675.032PX2KREX1RAPVC110.57
40M4015.01 ¼"25.61 ½"5930.030.327.940.40.41.61.62.055.060.575.040PX2KREX1RAPVC150.80
50SM5015.01 ½"26.12"8936.636.935.246.70.41.62.02.560.066.077.050SPX2KREX1RAPVC180.90
50M5015.02"26.92 ½"11541.041.340.453.00.61.62.02.570.077.077.050PX2KREX1RAPVC211.19
63SM6315.02"26.92 ½"11547.947.845.659.40.61.62.02.575.082.579.763SPX2KREX1RAPVC231.39
63M6315.02 ½"39.93"11553.754.054.665.80.61.62.02.580.088.080.363PX2KREX1RAPVC251.41
75SM7515.02 ½"39.93"14059.960.259.072.00.61.62.02.590.099.086.875SPX2KREX1RAPVC282.09
75M7515.03"41.53 ½"14064.264.266.778.40.61.62.53.0100.0110.088.375PX2KREX1RAPVC302.54
90M9020.03 ½"42.84"14075.375.676.290.30.81.63.154.0115.0126.5102.190PX2KREX1RAPVC323.71
100M10020.03 ½"42.84"20085.685.986.1101.40.81.63.154.0127.0139.7114.0100PX2KREX1RALSF334.81
Dimensions are displayed in millimeters unless otherwise stated

Technical Illustration

Additional Information

Why choose CMP Products?

Quality Assurance & Reliability CMP Products has an international reputation for quality and reliability and is highly regarded as the leading specialist in the design and manufacture of cable glands and accessories for industrial and explosive atmospheres. This position as market leader is maintained by listening to our customers and understanding their needs, to ensure that our solutions are practical to install and fully compliant with the latest industry standards and specifications.

Read more

NEMA 250 & IEC 60529

The table included on this page is provided for comparison purposes between typical NEMA 250 and IEC 60529 ratings.

Read more

Deluge Protection Specification DTS 01:91

The DTS:01 Test Specification was developed by Shell UK in conjunction with ERA Technology, based in Leatherhead, Surrey. Since its inception in 1991 it has been widely accepted by all major offshore operating companies as the standard to meet with respect to deluge protection.

Read more

Visit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.

Sign up now