A2F100 | Ex eb, Ex db, Ex nR, Ex ta | Explosive Atmosphere Cable Gland For all types of Unarmoured & Braided Cables
We'd like to keep in touch
We have some exciting things in the pipeline - if you'd like to be the first to know please enter your email address below.
Internationally Approved, Explosive Atmosphere Cable Gland
- Complies 100% with IEC 60079-0 cable retention requirements
- No special conditions for safe use
- No external cable clamping required
- Displacement type flameproof seal
- Deluge protected
- -60°C to +130°C
- Internationlly marked, IECEx, ATEX
- Ingress disc available
| Design Specification | BS 6121:Part 1:1989, IEC 62444, EN 62444 |
| Mechanical Classifications* | Impact = Level 8, Retention = Class B |
| Enclosure Protection | IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only |
| ATEX Certificate | CML 18ATEX4311, CML 18ATEX1307 |
| UKEX Certificate | CML 21UKEX1247, CML 21UKEX4248 |
| Code of Protection | II 2G, II 1D Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da II 3G Ex nR IIC Gc, I M2 Ex db I Mb, Ex eb I Mb |
| Compliance Standards | EN 60079-0,1,7,15,31 |
* Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings
Certificates
Product Selection Table
Click here to view how to order
| Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Overall Cable Diameter 'A' | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Ozs) |
|||||||
| Standard | Option | ||||||||||||||
| Metric | Thread Length (Metric) 'E" | NPT | Thread Length (NPT) 'E' | NPT | Min | Max | Max | Max | Size | Type | Ordering Suffix | ||||
| 16 | M16 | 0.59 | - | - | - | 0.13 | 0.31 | 0.94 | 1.04 | 1.37 | 16 | A2F100 | 1RA | PVC04 | 2.47 |
| 20S16 | M20 | 0.59 | ½' | 0.78 | ¾' | 0.13 | 0.31 | 0.94 | 1.04 | 1.20 | 20S16 | A2F100 | 1RA | PVC04 | 2.82 |
| 20S | M20 | 0.59 | ½' | 0.78 | ¾' | 0.26 | 0.44 | 0.94 | 1.04 | 1.26 | 20S | A2F100 | 1RA | PVC04 | 2.47 |
| 20 | M20 | 0.59 | ½' | 0.78 | ¾' | 0.28 | 0.53 | 1.06 | 1.17 | 1.41 | 20 | A2F100 | 1RA | PVC05 | 3.17 |
| 20L | M20 | 0.59 | ½' | 0.78 | ¾' | 0.34 | 0.55 | 1.06 | 1.17 | 1.35 | 20L | A2F100 | 1RA | PVC05 | 3.17 |
| 25 | M25 | 0.59 | ¾' | 0.80 | 1' | 0.45 | 0.77 | 1.42 | 1.56 | 1.59 | 25 | A2F100 | 1RA | PVC09 | 5.64 |
| 25L | M25 | 0.59 | ¾' | 0.80 | 1' | 0.55 | 0.79 | 1.42 | 1.56 | 1.57 | 25L | A2F100 | 1RA | PVC09 | 5.64 |
| 32 | M32 | 0.59 | 1' | 0.98 | 1 ¼' | 0.75 | 1.00 | 1.61 | 1.78 | 1.52 | 32 | A2F100 | 1RA | PVC10 | 6.35 |
| 32L | M32 | 0.59 | 1' | 0.98 | 1 ¼' | 0.80 | 1.04 | 1.61 | 1.78 | 1.40 | 32L | A2F100 | 1RA | PVC10 | 6.35 |
| 40 | M40 | 0.59 | 1 ¼' | 1.01 | 1 ½' | 0.98 | 1.27 | 1.97 | 2.17 | 1.53 | 40 | A2F100 | 1RA | PVC13 | 8.82 |
| 50S | M50 | 0.59 | 1 ½' | 1.03 | 2' | 1.22 | 1.50 | 2.17 | 2.38 | 1.63 | 50S | A2F100 | 1RA | PVC15 | 11.64 |
| 50 | M50 | 0.59 | 2' | 1.06 | 2 ½' | 1.40 | 1.73 | 2.36 | 2.60 | 1.80 | 50 | A2F100 | 1RA | PVC18 | 12.35 |
| 63S | M63 | 0.59 | 2' | 1.06 | 2 ½' | 1.63 | 1.96 | 2.78 | 3.06 | 1.70 | 63S | A2F100 | 1RA | PVC21 | 19.75 |
| 63 | M63 | 0.59 | 2 ½' | 1.57 | 3' | 1.90 | 2.16 | 2.95 | 3.25 | 1.72 | 63 | A2F100 | 1RA | PVC23 | 19.40 |
| 75S | M75 | 0.59 | 2 ½' | 1.57 | 3' | 2.13 | 2.44 | 3.31 | 3.64 | 1.79 | 75S | A2F100 | 1RA | PVC26 | 25.75 |
| 75 | M75 | 0.59 | 3' | 1.63 | 3 ½' | 2.41 | 2.67 | 3.31 | 3.64 | 1.93 | 75 | A2F100 | 1RA | PVC26 | 20.46 |
| 90 | M90 | 0.94 | 3 ½' | 1.69 | 4' | 2.62 | 3.15 | 4.25 | 4.68 | 2.60 | 90 | A2F100 | 1RA | PVC31 | 60.32 |
| 100 | M100 | 0.94 | 3½" | 1.69 | 4" | 2.99 | 3.50 | 4.84 | 5.33 | 2.84 | 100 | A2F100 | 1RA | LSF33 | 79.72 |
| 115 | M115 | 0.94 | 4' | 1.73 | 5' | 3.39 | 3.85 | 5.25 | 5.78 | 2.67 | 115 | A2F100 | 1RA | LSF34 | 96.65 |
| 130 | M130 | 0.94 | 5' | 1.84 | - | 3.82 | 4.52 | 6.00 | 6.60 | 3.19 | 130 | A2F100 | 1RA | LSF35 | 143.57 |
| Dimensions are displayed in inches unless otherwise stated | |||||||||||||||
| Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Overall Cable Diameter 'A' | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Kgs) |
|||||||
| Standard | Option | ||||||||||||||
| Metric | Thread Length (Metric) 'E" | NPT | Thread Length (NPT) 'E' | NPT | Min | Max | Max | Max | Size | Type | Ordering Suffix | ||||
| 16 | M16 | 15.0 | - | - | - | 3.2 | 8.0 | 24.0 | 26.4 | 34.9 | 16 | A2F100 | 1RA | PVC04 | 0.07 |
| 20S16 | M20 | 15.0 | ½' | 19.9 | ¾' | 3.2 | 8.0 | 24.0 | 26.4 | 30.4 | 20S16 | A2F100 | 1RA | PVC04 | 0.08 |
| 20S | M20 | 15.0 | ½' | 19.9 | ¾' | 6.5 | 11.2 | 24.0 | 26.4 | 31.9 | 20S | A2F100 | 1RA | PVC04 | 0.07 |
| 20 | M20 | 15.0 | ½' | 19.9 | ¾' | 7.0 | 13.5 | 27.0 | 29.7 | 35.8 | 20 | A2F100 | 1RA | PVC05 | 0.09 |
| 20L | M20 | 15.0 | ½' | 19.9 | ¾' | 8.7 | 14.0 | 27.0 | 29.7 | 34.3 | 20L | A2F100 | 1RA | PVC05 | 0.09 |
| 25 | M25 | 15.0 | ¾' | 20.2 | 1' | 11.5 | 19.5 | 36.0 | 39.6 | 40.4 | 25 | A2F100 | 1RA | PVC09 | 0.16 |
| 25L | M25 | 15.0 | ¾' | 20.2 | 1' | 14.0 | 20.0 | 36.0 | 39.6 | 39.9 | 25L | A2F100 | 1RA | PVC09 | 0.16 |
| 32 | M32 | 15.0 | 1' | 25.0 | 1 ¼' | 19.0 | 25.5 | 41.0 | 45.1 | 38.5 | 32 | A2F100 | 1RA | PVC10 | 0.18 |
| 32L | M32 | 15.0 | 1' | 25.0 | 1 ¼' | 20.2 | 26.3 | 41.0 | 45.1 | 35.5 | 32L | A2F100 | 1RA | PVC10 | 0.18 |
| 40 | M40 | 15.0 | 1 ¼' | 25.6 | 1 ½' | 25.0 | 32.2 | 50.0 | 55.0 | 38.8 | 40 | A2F100 | 1RA | PVC13 | 0.25 |
| 50S | M50 | 15.0 | 1 ½' | 26.1 | 2' | 31.0 | 38.2 | 55.0 | 60.5 | 41.4 | 50S | A2F100 | 1RA | PVC15 | 0.33 |
| 50 | M50 | 15.0 | 2' | 26.9 | 2 ½' | 35.6 | 44.0 | 60.0 | 66.0 | 45.8 | 50 | A2F100 | 1RA | PVC18 | 0.35 |
| 63S | M63 | 15.0 | 2' | 26.9 | 2 ½' | 41.5 | 49.9 | 70.5 | 77.6 | 43.3 | 63S | A2F100 | 1RA | PVC21 | 0.56 |
| 63 | M63 | 15.0 | 2 ½' | 39.9 | 3' | 48.2 | 54.9 | 75.0 | 82.5 | 43.6 | 63 | A2F100 | 1RA | PVC23 | 0.55 |
| 75S | M75 | 15.0 | 2 ½' | 39.9 | 3' | 54.0 | 61.9 | 84.0 | 92.4 | 45.4 | 75S | A2F100 | 1RA | PVC26 | 0.73 |
| 75 | M75 | 15.0 | 3' | 41.5 | 3 ½' | 61.1 | 67.9 | 84.0 | 92.4 | 49.0 | 75 | A2F100 | 1RA | PVC26 | 0.58 |
| 90 | M90 | 24.0 | 3 ½' | 42.8 | 4' | 66.6 | 79.9 | 108.0 | 118.8 | 66.0 | 90 | A2F100 | 1RA | PVC31 | 1.71 |
| 100 | M100 | 24.0 | 3½" | 42.8 | 4" | 76.0 | 89.0 | 123.0 | 135.3 | 72.2 | 100 | A2F100 | 1RA | LSF33 | 2.26 |
| 115 | M115 | 24.0 | 4' | 44.0 | 5' | 86.0 | 97.9 | 133.4 | 146.7 | 67.9 | 115 | A2F100 | 1RA | LSF34 | 2.74 |
| 130 | M130 | 24.0 | 5' | 46.8 | - | 97.0 | 114.9 | 152.4 | 167.6 | 81.1 | 130 | A2F100 | 1RA | LSF35 | 4.07 |
| Dimensions are displayed in millimetres unless otherwise stated | |||||||||||||||
Why choose CMP Products?
Quality Assurance & Reliability CMP Products has an international reputation for quality and reliability and is highly regarded as the leading specialist in the design and manufacture of cable glands and accessories for industrial and explosive atmospheres. This position as market leader is maintained by listening to our customers and understanding their needs, to ensure that our solutions are practical to install and fully compliant with the latest industry standards and specifications.
Read moreSummary of the Basic Requirements of IEC 62444 & EN 62444
The following extracts outline the basic requirements and compliance testing of cable glands to IEC 62444 / EN 62444. A) Material - Metallic, Non-metallic or Composite B) Mechanical Properties - i. Cable Retention & Anchorage Type A or B - for cables without armour
Read moreProtection by Enclosure Against Mechanical Impact
It is critically important that enclosures afford a level of mechanical protection relevant to the area of installation that provides optimum electrical and operational safety. The international standard IEC 62262 covering ‘Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK Code)’ outlines the requirements for testing and rating of enclosures of different materials, so that careful selection to suit the application can be achieved.
Read moreVisit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.
Sign up now