Globally Approved, Hazardous (Classified) Location Cable Gland
• Aluminium, nickel plated or stainless steel design
• Increased cable range with removable insert
• Optional thread sizes
• -76°F to 230°F
• Class I Zone 1, 21 AEx e and Zone 2, 22 Class I Division 2 ABCD
• CEC Class I Zone 1 Ex e & Class I Division 2 ABCD
• Globally marked, cCSAus, IECEx & ATEX
• Heavy duty design
• Entry thread seal as standard
Patent granted: CA 2726252, US 8440919
| Design Specification | BS 6121:Part 1:1989, IEC 62444, EN 62444 |
| Mechanical Classifications* | Impact = Level 8, Retention = Class D |
| ATEX Certificate | CML 18ATEX1334X |
| UKEX Certificate | CML 21UKEX1260X |
| Code of Protection | II 2G 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da |
| Compliance Standards | EN 60079-0,1,7, EN 61241-0,1 |
| IECEx Certificate | IECEx CML 18.0191X |
| Code of Protection | Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da |
| Compliance Standards | IEC 60079-0,1,7 IEC 61241-1 |
| cCSAus Certificate | 2220601 |
| CSAus Code of Protection | Class II, Division 2, Groups E, F, and G; Class III, Division 2; Enclosure. Type 4X, Class I, Zone 1, Ex e: This product is suitable for Class I, Division 2 applications, when installed as per NEC 501.10(B)(4) |
| cCSA Code of Protection | Class I, Div. 2, Groups A, B, C and D; Class II, Div. 2, Groups E, F, and G; Class III, Div. 2; Encl. Type 4X. Ex e; |
| Compliance Standards | CAN/CSA-C22.2 Various Sections (See Certificate) CAN/CSA-E60079-0,7, CAN/CSA-E61241-1-1, ANSI/UL 514B Ed 5, ANSI/UL 50Ed 11, ANSI/UL 60079-0,7 |
| EAC Certificate (Formerly GOST R, K & B) | TC RU C-GB.AA87.B.00487 |
| UkrSEPRO | CU 19.0371X |
| RETIE Approval | 03866 |
| CCOE / PESO (India) Certificate | Ex d: P548696, Ex e: P533772 |
| Marine Approvals | LRS: 01/00172, DNV: TAE00000Y, ABS: 20-2022051-PDA, BV: 43180/A1BV |
| Ingress Protection Rating ** | IP66, IP67 & IP68 |
| NEMA Rating** | NEMA 4X** |
| Cable Gland Material | Copper Free (<0.4%) Aluminium, Nickel Plated Brass, Stainless Steel |
| Cable Type | Tray Cable & Cords, Unarmoured / Braid (IEC) |
| Sealing Technique | CMP Displacement Seal with Removable Insert |
| Sealing Area(s) | Cable Outer Jacket |
| ECAS Certificate | 24-03-106290/E24-03-110155/NB0007 |
Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
*** IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request.
Certificates
Product Selection Table
Click here to view how to order
| Order Reference (NPT) | Entry Thread 'C' | Minimum Thread Length 'E' | Cable Range 'A' | Cable Range 'A' | Across Flats 'D' | Across Corners 'D' | Nominal Assembly Length 'F' | Shroud | Approx Weight Aluminum (oz) |
|||||
| Insert | No Insert | |||||||||||||
| Aluminum | Nickel Plated Brass | Stainless Steel | NPT | NPT Option | Min | Max | Min | Max | Max | Max | ||||
| TC-050A028 | TC-050NB028 | TC-050SS028 | ½" | - | 0.78 | 0.13 | 0.28 | - | - | 1.20 | 1.32 | 1.20 | PVC06 | 1.94 |
| TC-075A028 | TC-075NB028 | TC-075SS028 | - | ¾" | 0.80 | 1.48 | 1.63 | 1.24 | PVC09 | 1.69 | ||||
| TC-050A055 | TC-050NB055 | TC-050SS055 | ½" | - | 0.78 | 0.26 | 0.41 | 0.41 | 0.55 | 1.20 | 1.32 | 1.20 | PVC06 | 1.94 |
| TC-075A055 | TC-075NB055 | TC-075SS055 | - | ¾" | 0.80 | 1.48 | 1.63 | 1.24 | PVC09 | 1.69 | ||||
| TC-075A079 | TC-075NB079 | TC-075SS079 | ¾" | - | 0.80 | 0.44 | 0.61 | 0.61 | 0.79 | 1.48 | 1.63 | 1.24 | PVC09 | 1.69 |
| TC-100A079 | TC-100NB079 | TC-100SS079 | - | 1" | 0.98 | 1.81 | 1.99 | 1.65 | PVC11 | 3.17 | ||||
| TC-100A104 | TC-100NB104 | TC-100SS104 | 1" | - | 0.98 | 0.67 | 0.85 | 0.85 | 1.04 | 1.81 | 1.99 | 1.65 | PVC11 | 3.88 |
| TC-125A104 | TC-125NB104 | TC-125SS104 | - | 1¼" | 1.01 | 2.05 | 2.25 | PVC13 | ||||||
| TC-125A127 | TC-125NB127 | TC-125SS127 | 1¼" | - | 1.01 | 0.93 | 1.10 | 1.10 | 1.27 | 2.05 | 2.25 | 1.65 | PVC13 | 4.94 |
| TC-150A127 | TC-150NB127 | TC-150SS127 | - | 1½" | 1.03 | 2.36 | 2.60 | PVC18 | ||||||
| TC-150A150 | TC-150NB150 | TC-150SS150 | 1½" | - | 1.03 | 1.22 | 1.37 | 1.37 | 1.50 | 2.36 | 2.60 | 1.65 | PVC18 | 6.00 |
| TC-200A150 | TC-200NB150 | TC-200SS150 | - | 2" | 1.06 | 2.95 | 3.25 | PVC23 | ||||||
| TC-200A174 | TC-200NB174 | TC-200SS174 | 2" | - | 1.06 | - | - | 1.40 | 1.74 | 2.76 | 3.03 | 1.63 | PVC21 | 8.64 |
| TC-250A174 | TC-250NB174 | TC-250SS174 | - | 2½" | 1.57 | 3.54 | 3.90 | PVC27 | ||||||
| TC-200A197 | TC-200NB197 | TC-200SS197 | 2" | - | 1.06 | - | - | 1.63 | 1.97 | 2.76 | 3.03 | 1.74 | PVC21 | 8.29 |
| TC-250A197 | TC-250NB197 | TC-250SS197 | - | 2½" | 1.57 | 3.54 | 3.90 | PVC27 | ||||||
| TC-250A220 | TC-250NB220 | TC-250SS220 | 2½" | - | 1.57 | - | - | 1.86 | 2.20 | 3.54 | 3.90 | 1.74 | PVC27 | 13.58 |
| TC-300A220 | TC-300NB220 | TC-300SS220 | - | 3" | 1.63 | 4.33 | 4.77 | PVC31 | ||||||
| TC-250A244 | TC-250NB244 | TC-250SS244 | 2½" | - | 1.57 | - | - | 2.13 | 2.44 | 3.54 | 3.90 | 1.79 | PVC28 | 13.58 |
| TC-300A244 | TC-300NB244 | TC-300SS244 | - | 3" | 1.63 | 4.33 | 4.77 | PVC31 | ||||||
| TC-300A268 | TC-300NB268 | TC-300SS268 | 3" | - | 1.63 | - | - | 2.41 | 2.68 | 4.33 | 4.77 | 1.79 | PVC31 | 23.63 |
| TC-350A268 | TC-350NB268 | TC-350SS268 | - | 3½" | 1.69 | 4.84 | 5.33 | LSF32 | ||||||
| TC-350A315 | TC-350NB315 | TC-350SS315 | 3½" | - | 1.69 | - | - | 2.62 | 3.15 | 4.84 | 5.33 | 2.50 | LSF32 | 34.22 |
| TC-400A315 | TC-400NB315 | TC-400SS315 | - | 4" | 1.73 | 5.25 | 5.78 | LSF33 | ||||||
| TC-400A354 | TC-400NB354 | TC-400SS354 | 4" | - | 1.73 | - | - | 2.99 | 3.54 | 5.25 | 5.78 | 2.36 | LSF34 | 38.80 |
| Order code example: TC-050A028 - “TC” (Type Gland) - “050” (½” NPT Thread) - ‘A’ (Material Aluminum) - “028”(Max Cable Diameter 0.28”) | ||||||||||||||
| Dimensions displayed in inches unless otherwise stated | ||||||||||||||
| Order Reference (NPT) | Entry Thread "C" | Minimum Thread Length "E" | Cable Range "A" | Cable Range "A" | Across Flats "D" | Across Corners "D" | Nominal Assembly Length "F" | Shroud | Approx Weight Aluminum (Kgs) |
|||||
| Insert | No Insert | |||||||||||||
| Aluminum | Nickel Plated Brass | Stainless Steel | NPT | NPT Option | Min | Max | Min | Max | Max | Max | ||||
| TC-050A028 | TC-050NB028 | TC-050SS028 | ½" | - | 19.9 | 3.2 | 7.0 | - | - | 30.5 | 33.5 | 30.5 | PVC05 | 0.05 |
| TC-075A028 | TC-075NB028 | TC-075SS028 | - | ¾" | 20.2 | 37.6 | 40.4 | 31.5 | 0.05 | |||||
| TC-050A055 | TC-050NB055 | TC-050SS055 | ½" | - | 19.9 | 6.5 | 10.3 | 10.3 | 14.0 | 30.5 | 33.5 | 30.5 | PVC06 | 0.05 |
| TC-075A055 | TC-075NB055 | TC-075SS055 | - | ¾" | 20.2 | 37.6 | 41.4 | 31.5 | 0.05 | |||||
| TC-075A079 | TC-075NB079 | TC-075SS079 | ¾" | - | 20.2 | 11.1 | 15.5 | 15.5 | 20.0 | 37.6 | 41.4 | 31.5 | PVC09 | 0.05 |
| TC-100A079 | TC-100NB079 | TC-100SS079 | - | 1" | 25.0 | 46.0 | 49.8 | 41.9 | 0.09 | |||||
| TC-100A104 | TC-100NB104 | TC-100SS104 | 1" | - | 25.0 | 17.0 | 21.7 | 21.7 | 26.3 | 46.0 | 50.5 | 41.9 | PVC11 | 0.11 |
| TC-125A104 | TC-125NB104 | TC-125SS104 | - | 1¼" | 25.6 | 52.1 | 56.1 | |||||||
| TC-125A127 | TC-125NB127 | TC-125SS127 | 1¼" | - | 25.6 | 23.5 | 27.9 | 27.9 | 32.2 | 52.1 | 57.2 | 41.9 | PVC13 | 0.14 |
| TC-150A127 | TC-150NB127 | TC-150SS127 | - | 1½" | 26.1 | 59.9 | 64.8 | |||||||
| TC-150A150 | TC-150NB150 | TC-150SS150 | 1½" | - | 26.1 | 31.0 | 34.7 | 34.7 | 38.2 | 59.9 | 66.0 | 41.9 | PVC21 | 0.17 |
| TC-200A150 | TC-200NB150 | TC-200SS150 | - | 2" | 26.9 | 74.9 | 81.0 | |||||||
| TC-200A174 | TC-200NB174 | TC-200SS174 | 2" | - | 26.9 | - | - | 35.6 | 44.1 | 70.1 | 75.7 | 41.4 | PVC21 | 0.24 |
| TC-250A174 | TC-250NB174 | TC-250SS174 | - | 2½" | 39.9 | 89.9 | 97.3 | |||||||
| TC-200A197 | TC-200NB197 | TC-200SS197 | 2" | - | 26.9 | - | - | 41.5 | 50.1 | 70.1 | 77.0 | 44.2 | PVC28 | 0.24 |
| TC-250A197 | TC-250NB197 | TC-250SS197 | - | 2½" | 39.9 | 89.9 | 97.3 | |||||||
| TC-250A220 | TC-250NB220 | TC-250SS220 | 2½" | - | 39.9 | - | - | 47.2 | 56.0 | 89.9 | 97.3 | 44.2 | PVC28 | 0.38 |
| TC-300A220 | TC-300NB220 | TC-300SS220 | - | 3" | 41.5 | 110.0 | 118.9 | |||||||
| TC-250A244 | TC-250NB244 | TC-250SS244 | 2½" | - | 39.9 | - | - | 54.0 | 62.0 | 89.9 | 99.1 | 45.5 | PVC31 | 0.38 |
| TC-300A244 | TC-300NB244 | TC-300SS244 | - | 3" | 41.5 | 110.0 | 118.9 | |||||||
| TC-300A268 | TC-300NB268 | TC-300SS268 | 3" | - | 41.5 | - | - | 61.0 | 68.0 | 110.0 | 118.9 | 45.5 | PVC31 | 0.67 |
| TC-350A268 | TC-350NB268 | TC-350SS268 | - | 3½" | 42.8 | 122.9 | 132.8 | |||||||
| TC-350A315 | TC-350NB315 | TC-350SS315 | 3½" | - | 42.8 | - | - | 66.6 | 80.0 | 122.9 | 132.8 | 63.5 | LSF33 | 0.97 |
| TC-400A315 | TC-400NB315 | TC-400SS315 | - | 4" | 44.0 | 133.4 | 144.0 | |||||||
| TC-400A354 | TC-400NB354 | TC-400SS354 | 4" | - | 44.0 | - | - | 76.0 | 90.0 | 133.4 | 144.0 | 59.9 | LSF34 | 1.10 |
| Dimensions displayed in millimeters unless otherwise stated | ||||||||||||||
Why choose CMP Products?
Quality Assurance & Reliability CMP Products has an international reputation for quality and reliability and is highly regarded as the leading specialist in the design and manufacture of cable glands and accessories for industrial and explosive atmospheres. This position as market leader is maintained by listening to our customers and understanding their needs, to ensure that our solutions are practical to install and fully compliant with the latest industry standards and specifications.
Read moreIngress Protection to IEC 60529
Ingress Protection is applicable to all types of electrical and instrument enclosures, as well as cable glands, and is commonly abbreviated to ‘IP’ with additional digits which follow this abbreviation to define the level of environmental protection.
Read moreCombating Galvanic Corrosion at CMP
The type and thickness of nickel coatings applied to brass cable glands varies significantly around the world, and many of the solutions adopted are inherently porous, meaning that they are unable to provide complete protection against chemical attack, corrosion, or material break-down. There are typically two types of nickel plating in common use, these being electro nickel plating and electro-less nickel plating.
Read moreCertification to IEC 60079 Based Standards
There are some subtle differences when selecting cable glands, or cable connectors for use in Zones. This is because the National Electric Code (NEC), API and Canadian Electric Code (CEC) wiring requirements take precedence in the United States and Canada over normal IEC practices.
Read moreCertification
Before products, equipment, or protective systems can be selected for installation in explosive atmospheres they should first be certified as being suitable for that application. A Certificate of Conformity for equipment intended for use in Explosive Atmospheres is evidence that the product, equipment or protective system conforms and has been tested to a relevant standard.
Read moreCable Glands Permitted Under NEC & CEC Wiring Rules
In the IEC world, there are essentially two different types of cables, armored and unarmored, whilst the test parameters for the cable gland varies, depending on the cable type, the cable glands themselves are not required to be tested on cables, but are instead tested on steel mandrels. Conversely, in the NEC and CEC world, cable glands are tested on cables, with very different test parameters applicable to the different types of armored and unarmored cables. Before selecting a cable gland for use in a classified location, the cable must be permitted and approved for the location and then the cable gland must also be listed for use on that specific type of cable.
Read moreCable Glands Permitted in Hazardous Locations
Under NEC and CEC wiring code rules the use of IEC certified product is not automatically permitted under the zone classification methods. Globally there are now three methods of selection or application of cable entry devices.
Read moreCables Permitted in Hazardous Locations
In accordance with API 500 (14F), API 505 (14FZ), National Electrical Code (NEC) 2020 and C22.1-18 (Canadian Electric Code) any cable for use in a classified location must firstly be of a type permitted in the location, and secondly be tested and approved to standards specific to the application.
Read moreTypical Class I Zone 2 & Safe Area Sealing Methods
An illustrative example of Typical Class I Zone 2 & Safe Area Sealing Methods
Read moreTypical Class I Zone 1 & 2 Sealing Methods
An illustrative example of Typical Class I Zone 1 & 2 Sealing Methods
Read moreTypical Class I Division 1 & 2 Sealing Methods
An illustrative example of Typical Class I Division 1 & 2 Sealing Methods
Read moreIECEx Certified Equipment
Under normal circumstances, because of the national deviations or national differences inherent within the ANSI, UL, ISA and CSA standards published in North America it is not possible to select IECEx ‘only’ certified equipment for use in classified locations defined by NFPA (NEC) Article 505 & API 505 (14FZ), or C22.1-18 Section 18, unless that equipment is also certified and marked with an AEx or Ex codification signifying that it has been assessed, tested and certified to all of the relevant ANSI, UL, ISA or CSA standards, and is installed in accordance with the applicable wiring method and installation code.
Read moreUnited States Coast Guard (USCG)
The USCG permits foreign flagged vessels to operate in the Outer Continental Shelf (OCS), however, any Explosionproof or Flameproof type ‘d’ equipment must comply with the requirements set out in USCG 46 CFR. Many of these vessels are classified to international standards, utilizing both IECEx and/or ATEX certified equipment in classified locations.
Read moreVisit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.
View Profile