- Home
- Cable Glands
- Products
- Explosive Atmosphere
- FORTRA TFUV EMC | Explosive Atmospheres Cable Gland
FORTRA TFUV EMC | Explosive Atmospheres Cable Gland For All Types of Armoured & Braided / Screened Cables
- Ex d
- Ex e
- Ex nR
- Ex ta
FORTRA TFUV EMC | Explosive Atmospheres Cable Gland For All Types of Armoured & Braided / Screened Cables
We'd like to keep in touch
We have some exciting things in the pipeline - if you'd like to be the first to know please enter your email address below.
- Unique patented captive Adaptive Cone for all types of armour or braid, with captive AnyWay clamping ring
- Metal-to-metal armour clamping; no installation or inspection ambiguity
- Unique grounding device provides a 360 degree, low impedance contact around a cable EMC/VFD screen for superior EMC performance, or for continuity to a lead sheath
- Fewer installation steps for faster process. Unique ‘Quick’ Thread for faster armour clamping
- Flameproof inner diaphragm seal – safe, reliable & robust; no installation or inspection ambiguity
- Excellent cold flow performance with third party verified test report on cable types used globally
- Outer seal with wider cable acceptance, meaning fewer stocking sizes
- IP66, 67, 68, 69 & 69K as standard with fully enclosed/protected deluge seal for third party compliance to DTS 01:91
- Compact design; ideal for applications with limited installation space
- Fewer tools required for installation and maintenance
Tightening tools may be required to aid installation. For further information, please click here.
| Design Specification | BS 6121-1, IEC 62444, EN 62444 |
| Mechanical Classifications* | 16 -20S Impact = Category 6, 20 -130 Impact = Category 8, Wire Armour Anchorage = Type D, Braid Anchorage = Type C |
| Enclosure Protection | 16-20S IK08 to IEC 62262 (7 joules) 20-130 IK08 to IEC 62262 (20 joules) |
| Electrical Classifications * | Category B (Category A when used with braid, tape or pliable wire armour cables) |
| Ingress Protection Rating** | IP66, IP67, IP68***, IP69 and IP69K |
| Deluge Protection Compliance | DTS 01:91 |
| Temperature for permanent application | -60 to +105 °C |
| Armour Clamping | Captive ‘Adaptive’ Armour Cone and Captive ‘AnyWay’ Clamping Ring |
| Seal Material | LSF Halogen Free Silicone |
| Sealing Technique | CMP Inner Flameproof Diaphragm Seal and Outer Environmental/Load Retention Seal |
| Sealing Area(s) | Cable Inner Bedding and Cable Outer Sheath |
| Type | Brass†, Electroless Nickel Plated Brass, Stainless Steel |
| Cable Type (s) | W: Steel / Served Wire Armour (SWA), Aluminium Wire Armour (AWA) X: Pliable Wire Armour (PWA), Steel Tape Armour (STA), Aluminium Strip Armour (ASA), Screened Flexible (EMC) Wire Braid (e.g. CY/SY), Wire Braid Armour (e.g. SWB) |
| ATEX Certificate | CML 24ATEX1333X CML 24ATEX4334X |
| UKEX Certificate | CML 24UKEX1335X CML 24UKEX4336X |
| Code of Protection | I M2 Ex db I Mb, Ex eb I Mb; II 2G 3G 1D Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da, Ex nR IIC Gc |
| Compliance Standards | EN 60079-0, -1, -7, -15, -31 |
| IECEx Certificate | IECEx CML 24.0137X |
| Code of Protection | Ex db I Mb, Ex eb I Mb, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da, Ex nR IIC Gc |
| Compliance Standards | IEC 60079-0, -1, -7, -15, -31 |
| EAC Certificate | EAЭC KZ 7100841.01.01.07859 |
| Code of Protection | 1Ex db IIC Gb X, 1Ex eb IIC Gb X, 2Ex nR IIC Gc X, Ex ta IIIC Da X |
| cCSAus Certificate | Contact CMP for full details |
| UkrSEPRO | UkrSEPRO CЦ 25.1094X |
| Marine Approvals | Lloyds: LR22320739TA, ABS: 25-0285992-PDA, DNV: TAE000000Y, BV: 43180 |
| INMETRO Certificate | INMETRO TÜV 25.0801X |
| Industrial Certificate | CML 24CA17921 |
| Taiwan Certificate | Taiwan ML141200751312 |
| PESO | PESO P640727/1, P640727/5 , PESO P640726/1 |
| CCC Certificate | CCC 2026322313007163 |
* Mechanical and Electrical Classifications applied as per IEC 62444 and EN 62444
** When CMP installation accessories are used. Refer to www.cmp-products.com for further information
*** IP68 tested to a depth of 30 metres for 7 days, alternative depths / durations can be provided on request
Certificates
Product Selection Table
Click here to view how to order
| Combined Ordering Reference | Entry Thread Size ‘TS’ | Entry Thread Pitch | Minimum Thread Length ‘TL’ | Inner Cable Bedding Diameter ‘IB’ | Cable Diameter Over Screen or Lead Sheath 'IS' | Overall Cable Diameter ‘OS’ | Armour Thickness | Max Across Flats | Max Across Corners ‘AC’ | Max Protrusion Length ‘PL’ | Shroud Size | Assembly Weight (KG) |
||||||||
| Size | Type | Ordering Suffix | Min | Max | Min | Max | Min | Max | W Cable Type | X Cable Type | ||||||||||
| Mix | Max | Min | Max | |||||||||||||||||
| 20S16‡ | TFUV | 502 | M20 | 0.06 | 0.59 | 0.12 | 0.28 | 0.13 | 0.31 | 0.24 | 0.52 | 0.03 | 0.05 | 0.01 | 0.04 | 0.94 | 1.04 | 2.81 | 4 | 0.14 |
| 20S‡ | TFUV | 502 | M20 | 0.06 | 0.59 | 0.24 | 0.31 | 0.24 | 0.31 | 0.37 | 0.63 | 0.03 | 0.05 | 0.01 | 0.04 | 0.94 | 1.04 | 2.81 | 4 | 0.14 |
| 20 | TFUV | 502 | M20 | 0.06 | 0.59 | 0.31 | 0.47 | 0.32 | 0.47 | 0.49 | 0.82 | 0.03 | 0.05 | 0.02 | 0.04 | 1.2 | 1.32 | 2.76 | 6 | 0.22 |
| 25 | TFUV | 503 | M25 | 0.06 | 0.59 | 0.43 | 0.63 | 0.44 | 0.63 | 0.63 | 1.03 | 0.05 | 0.06 | 0.02 | 0.05 | 1.48 | 1.63 | 3.21 | 9 | 0.35 |
| 32 | TFUV | 504 | M32 | 0.06 | 0.59 | 0.67 | 0.91 | 0.67 | 0.91 | 0.85 | 1.33 | 0.06 | 0.08 | 0.02 | 0.05 | 1.81 | 1.99 | 3.54 | 11 | 0.54 |
| 40 | TFUV | 505 | M40 | 0.06 | 0.59 | 0.87 | 1.18 | 0.87 | 1.18 | 1.1 | 1.59 | 0.06 | 0.08 | 0.02 | 0.06 | 2.17 | 2.38 | 3.66 | 15 | 0.76 |
| 50 | TFUV | 506 | M50 | 0.06 | 0.59 | 1.16 | 1.73 | 1.18 | 1.73 | 1.5 | 2.09 | 0.08 | 0.1 | 0.02 | 0.06 | 2.76 | 3.03 | 4 | 21 | 1.2 |
| 63 | TFUV | 507 | M63 | 0.06 | 0.59 | 1.63 | 2.17 | 1.64 | 2.17 | 2.05 | 2.6 | 0.08 | 0.1 | 0.02 | 0.06 | 3.15 | 3.46 | 4.45 | 25 | 1.49 |
| 75 | TFUV | 508 | M75 | 0.06 | 0.59 | 2.11 | 2.64 | 2.11 | 2.64 | 2.54 | 3.09 | 0.1 | 0.12 | 0.02 | 0.06 | 3.94 | 4.33 | 4.43 | 30 | 2.61 |
| 90 | TFWV/TFXV # | 509 | M90 | 0.08 | 0.94 | 2.6 | 3.07 | 2.6 | 3.07 | 2.95 | 3.56 | 0.12 | 0.16 | 0.03 | 0.06 | 4.49 | 4.94 | 5.93 | 32 | 4.91 |
| 100 | TFWV/TFXV # | 5010 | M100 | 0.08 | 0.94 | 2.99 | 3.5 | 3 | 3.5 | 3.39 | 4 | 0.12 | 0.16 | 0.03 | 0.06 | 4.84 | 5.33 | 6.32 | 33 | 5.22 |
| 115 | TFWV/TFXV # | 5011 | M115 | 0.08 | 0.94 | 3.78 | 3.86 | 3.39 | 3.78 | 3.98 | 4.35 | 0.12 | 0.16 | 0.03 | 0.06 | 5.24 | 5.76 | 7.11 | 34 | 7.25 |
| 130 | TFWV/TFXV # | 5012 | M130 | 0.08 | 0.94 | 3.84 | 4.49 | 3.84 | 4.49 | 4.33 | 4.86 | 0.12 | 0.16 | 0.03 | 0.06 | 6.02 | 6.63 | 7.54 | 35 | 9.47 |
| Dimensions listed are for cable glands with metric equipment entry threads only. Alternative entry thread types e.g. NPT are available; dimensions may vary. | ||||||||||||||||||||
| Part numbers listed are for nickel plated brass cable glands only. Alternative materials are available. ‡ Also available in M16 on request | ||||||||||||||||||||
| For material options, please change the ‘material suffix’, which is the first digit in the ‘ordering suffix’. Brass = 0, Stainless Steel = 4 and Nickel Plated Brass = 5. Examples: 20TFUV002 = Brass M20, 40TFUV405 = Stainless Steel M40 |
||||||||||||||||||||
| For NPT thread options, please change the second digit in the ‘ordering suffix’ to 3 (denotes NPT) and change the final digit to denote the thread size i.e. ½” = 31, ¾” = 32, 1” = 33, 1-1/4” = 34, 1-1/2” = 35, 2” = 36, 2-1/2” = 37, 3” = 38, 3-1-2” = 39, 4” = 310, 5” = 312. Examples: 32TFUV533 = Nickel Plated Brass 1” NPT, 50TFUV436 = Stainless Steel 2” NPT |
||||||||||||||||||||
| # Sizes 90 to 130 are supplied with a single-sided armour or braid cone. Order TFWV for W cable types or TFXV for X cable types as per table above | ||||||||||||||||||||
| Combined Ordering Reference | Entry Thread Size ‘TS’ | Entry Thread Pitch | Minimum Thread Length ‘TL’ | Inner Cable Bedding Diameter ‘IB’ | Cable Diameter Over Screen or Lead Sheath 'IS' | Overall Cable Diameter ‘OS’ | Armour Thickness | Max Across Flats | Max Across Corners ‘AC’ | Max Protrusion Length ‘PL’ | Shroud Size | Assembly Weight (KG) |
||||||||
| Size | Type | Ordering Suffix | Min | Max | Min | Max | Min | Max | W Cable Type | X Cable Type | ||||||||||
| Mix | Max | Min | Max | |||||||||||||||||
| 20S16‡ | TFUV | 502 | M20 | 1.5 | 15 | 3.1 | 7 | 3.2 | 8 | 6.1 | 13.2 | 0.8 | 1.25 | 0.3 | 1 | 24 | 26.4 | 71.5 | 4 | 0.14 |
| 20S‡ | TFUV | 502 | M20 | 1.5 | 15 | 6 | 8 | 6.1 | 8 | 9.5 | 15.9 | 0.8 | 1.25 | 0.3 | 1 | 24 | 26.4 | 71.5 | 4 | 0.14 |
| 20 | TFUV | 502 | M20 | 1.5 | 15 | 8 | 12 | 8.1 | 12 | 12.5 | 20.9 | 0.8 | 1.25 | 0.4 | 1 | 30.5 | 33.6 | 70 | 6 | 0.22 |
| 25 | TFUV | 503 | M25 | 1.5 | 15 | 11 | 16 | 11.1 | 16 | 16 | 26.2 | 1.25 | 1.6 | 0.4 | 1.2 | 37.5 | 41.3 | 81.5 | 9 | 0.35 |
| 32 | TFUV | 504 | M32 | 1.5 | 15 | 17 | 23 | 17.1 | 23 | 21.5 | 33.9 | 1.6 | 2 | 0.4 | 1.2 | 46 | 50.6 | 90 | 11 | 0.54 |
| 40 | TFUV | 505 | M40 | 1.5 | 15 | 22 | 30 | 22.1 | 30 | 28 | 40.4 | 1.6 | 2 | 0.4 | 1.6 | 55 | 60.5 | 93 | 15 | 0.76 |
| 50 | TFUV | 506 | M50 | 1.5 | 15 | 29.5 | 44 | 30 | 44 | 38 | 53.2 | 2 | 2.5 | 0.6 | 1.6 | 70 | 77 | 101.5 | 21 | 1.2 |
| 63 | TFUV | 507 | M63 | 1.5 | 15 | 41.5 | 55 | 41.6 | 55 | 52 | 66 | 2 | 2.5 | 0.6 | 1.6 | 80 | 88 | 113 | 25 | 1.49 |
| 75 | TFUV | 508 | M75 | 1.5 | 15 | 53.5 | 67 | 53.6 | 67 | 64.5 | 78.5 | 2.5 | 3.15 | 0.6 | 1.6 | 100 | 110 | 112.5 | 30 | 2.61 |
| 90 | TFWV/TFXV # | 509 | M90 | 2 | 24 | 66 | 78 | 66.1 | 78 | 75 | 90.5 | 3.15 | 4 | 0.8 | 1.6 | 114 | 125.4 | 150.5 | 32 | 4.91 |
| 100 | TFWV/TFXV # | 5010 | M100 | 2 | 24 | 76 | 89 | 76.1 | 89 | 86 | 101.5 | 3.15 | 4 | 0.8 | 1.6 | 123 | 135.3 | 160.5 | 33 | 5.22 |
| 115 | TFWV/TFXV # | 5011 | M115 | 2 | 24 | 96 | 98 | 86.1 | 96 | 101 | 110.5 | 3.15 | 4 | 0.8 | 1.6 | 133 | 146.3 | 180.5 | 34 | 7.25 |
| 130 | TFWV/TFXV # | 5012 | M130 | 2 | 24 | 97.5 | 114 | 97.6 | 114 | 110 | 123.5 | 3.15 | 4 | 0.8 | 1.6 | 153 | 168.3 | 191.5 | 35 | 9.47 |
| Dimensions listed are for cable glands with metric equipment entry threads only. Alternative entry thread types e.g. NPT are available; dimensions may vary. | ||||||||||||||||||||
| Part numbers listed are for nickel plated brass cable glands only. Alternative materials are available. ‡ Also available in M16 on request | ||||||||||||||||||||
| For material options, please change the ‘material suffix’, which is the first digit in the ‘ordering suffix’. Brass = 0, Stainless Steel = 4 and Nickel Plated Brass = 5. Examples: 20TFUV002 = Brass M20, 40TFUV405 = Stainless Steel M40 |
||||||||||||||||||||
| For NPT thread options, please change the second digit in the ‘ordering suffix’ to 3 (denotes NPT) and change the final digit to denote the thread size i.e. ½” = 31, ¾” = 32, 1” = 33, 1-1/4” = 34, 1-1/2” = 35, 2” = 36, 2-1/2” = 37, 3” = 38, 3-1-2” = 39, 4” = 310, 5” = 312. Examples: 32TFUV533 = Nickel Plated Brass 1” NPT, 50TFUV436 = Stainless Steel 2” NPT |
||||||||||||||||||||
| # Sizes 90 to 130 are supplied with a single-sided armour or braid cone. Order TFWV for W cable types or TFXV for X cable types as per table above | ||||||||||||||||||||
DIN 40050 Definitions
The following page provides an explanation of ingress protection codes according to DIN 40050-9 (liquids) and IEC 60529 (dusts).
Read moreElectrical Safety in the Work Place
Local codes of practice or regulations may be in force to ensure that safety is maintained to eliminate the possibility of accidents arising from the danger of electricity. These dangers would include electric shock, burns, fire, explosion and arcing. In the United Kingdom the ESQCR 2002, and amendments 2006 (S.I. No. 1521) and 2009 (S.I. No. 639), introduced under Statutory Instrument No. 2665, and the Electricity at Work Regulations 1989 (EAW Regulations), which came into force on 1 April 1990, comprehensively deal with this subject.
Read moreEMC Performance
Tests were carried out in an anechoic chamber using various CMP cable glands with a section of cable connected to it which would act as an aerial. A known electrical radiation source was used to introduce interference into the chamber, and the level of radiation in the cable shield was measured.
Read moreVisit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.
Log in now












