FORTRA TFU | Explosive Atmospheres Cable Gland For All Types of Armoured & Braided / Screened Cables

  • Unique patented captive ‘Adaptive’ Cone for all types of armour or braid, with captive ‘AnyWay’ clamping ring
  • Metal-to-metal armour clamping; no installation or inspection ambiguity
  • Fewer installation steps for faster process. Unique ‘Quick’ Thread for faster armour clamping
  • Flameproof inner diaphragm seal – safe, reliable & robust; no installation or inspection ambiguity
  • Excellent cold flow performance with third party verified test report on cable types used globally
  • Outer seal with wider cable acceptance, meaning fewer stocking sizes
  • IP66, 67, 68, 69 & 69K as standard with fully enclosed/protected deluge seal for third party compliance to DTS 01:91 & NEMA 4X & 6P
  • Compact design; ideal for applications with limited installation space
  • Fewer tools required for installation and maintenance
Design Specification BS 6121-1, IEC 62444, EN 62444
Mechanical Classifications* 16-20S Impact = Category 6, 20-130 Impact = Category 8
Wire Armour Anchorage = Type D, Braid Anchorage = Type C
Enclosure Protection 16-20S IK08 to IEC 62262 (7 Joules)
20-130 IK10 to IEC 62262 (20 Joules)
Electrical Classifications * Category B (Category A when used with braid, tape or pliable wire armour cables)
Ingress Protection Rating** IP66, IP67, IP68***, IP69, IP69K
Type Rating** NEMA 4X & 6P
Deluge Protection Compliance DTS 01:91
Service Temperature -60 to +105 °C
Armour Clamping Captive ‘Adaptive’ Armour Cone and Captive ‘AnyWay’ Clamping Ring
Seal Material LSF Halogen Free Silicone
Sealing Technique CMP Inner Flameproof Diaphragm Seal and Outer Environmental/Load Retention Seal
Mechanical Classification Cable Inner Bedding and Cable Outer Sheath
Type Material Options Brass†, Nickel Plated Brass, Stainless Steel
Cable Type (s) W: Steel / Served Wire Armour (SWA), Aluminium Wire Armour (AWA)
X: Pliable Wire Armour (PWA), Steel Tape Armour (STA), Aluminium Strip Armour (ASA), Screened Flexible (EMC) Wire Braid (e.g. CY/SY), Wire Braid Armour (e.g. SWB)
Marine Approvals Lloyds: LR22320255TA, ABS: 25-0285992-PDA, DNV: TAE000000Y
Industrial Certificate CML 24CA17921
ATEX Certificate ATEX: CML 24ATEX1333X
IECEx Certificate IECEx CML 24.0137X
UKEX Certificate UKEX: CML 24UKEX1335X
UKEX: CML 24UKEX4336X
EAC Certificate EAЭC KZ 7100841.01.01.07859
cCSAus Certificate Contact CMP for full details
UkrSEPRO UkrSEPRO CЦ 25.1094X
INMETRO Certificate INMETRO TÜV 25.0801X
Taiwan Certificate Taiwan ML141200751312
CCC Certificate CCC 2026322313007163
PESO PESO P640727/1, P640727/5 , PESO P640726/1

* Mechanical and Electrical Classifications applied as per IEC 62444 and EN 62444
** When CMP installation accessories are used. Refer to www.cmp-products.com for further information
*** IP68 tested to a depth of 30 metres for 7 days, alternative depths / durations can be provided on
request
† Not available with NEMA type 4X and 6P

Jump to technical illustration   

Certificates

Click here to view Certificates

Product Selection Table

Click here to view how to order

Combined Ordering Reference Entry
Thread
Size
‘TS’
Entry Thread PitchMinimum Thread Length
‘TL’
Inner Cable Bedding
Diameter ‘IB’
Overall Cable
Diameter ‘OS’
Armour ThicknessMax
Across
Flats
Max
Across
Corners
‘AC’
Max Protrusion Length
‘PL’
Shroud
Size
Assembly
Weight
(oz)
SizeTypeOrdering SuffixMinMaxMinMaxW Cable TypeX Cable Type
MixMaxMinMax
20S16‡TFU502M200.060.590.120.280.240.520.030.050.010.040.941.042.8140.14
20S‡TFU502M200.060.590.240.460.370.630.030.050.010.040.941.042.8140.14
20TFU502M200.060.590.310.550.490.820.030.050.020.041.21.322.7660.22
25TFU503M250.060.590.430.770.631.030.050.060.020.051.481.633.2190.35
32TFU504M320.060.590.671.040.851.330.060.080.020.051.811.993.54110.54
40TFU505M400.060.590.871.261.11.590.060.080.020.062.172.383.66150.76
50TFU506M500.060.591.161.731.52.090.080.10.020.062.763.034211.2
63TFU507M630.060.591.632.172.052.60.080.10.020.063.153.464.45251.49
75TFU508M750.060.592.112.682.543.090.10.120.020.063.944.334.43302.61
90TFU509M900.080.942.63.092.953.560.120.160.030.064.494.945.93324.91
100TFU5010M1000.080.942.993.563.3940.120.160.030.064.845.336.32335.22
115TFU5011M1150.080.943.393.863.984.350.120.160.030.065.245.767.11347.25
130TFU5012M1300.080.943.844.534.334.860.120.160.030.066.026.637.54359.47
Dimensions listed are for cable glands with metric equipment entry threads only. Alternative entry thread types e.g. NPT are available; dimensions may vary.
Part numbers listed are for nickel plated brass cable glands only. Alternative materials are available. ‡ Also available in M16 on request
For material options, please change the ‘material suffix’, which is the first digit in the ‘ordering suffix’. Brass = 0, Stainless Steel = 4 and Nickel Plated Brass = 5.
Examples: 20TFU002 = Brass M20, 40TFU405 = Stainless Steel M40
For NPT thread options, please change the second digit in the ‘ordering suffix’ to 3 (denotes NPT) and change the final digit to denote the thread size i.e. ½” = 31, ¾” = 32, 1” = 33, 1-1/4” = 34,
1-1/2” = 35, 2” = 36, 2-1/2” = 37, 3” = 38, 3-1-2” = 39, 4” = 310, 5” = 312. Examples: 32TFU533 = Nickel Plated Brass 1” NPT, 50TFU436 = Stainless Steel 2” NPT
Sizes 90-130 are provided with a reversible armour cone. The ‘X’ side clamps 0.8 – 1.6 mm and the ‘W’ side clamps 3.15 – 4.0 mm
Combined Ordering Reference Entry
Thread
Size
‘TS’
Entry Thread PitchMinimum Thread Length
‘TL’
Inner Cable Bedding
Diameter ‘IB’
Overall Cable
Diameter ‘OS’
Armour ThicknessMax
Across
Flats
Max
Across
Corners
‘AC’
Max Protrusion Length
‘PL’
Shroud
Size
Assembly
Weight
(oz)
SizeTypeOrdering SuffixMinMaxMinMaxW Cable TypeX Cable Type
MixMaxMinMax
20S16‡TFU502M201.5153.176.113.20.81.250.312426.471.540.14
20S‡TFU502M201.515611.69.515.90.81.250.312426.471.540.14
20TFU502M201.51581412.520.90.81.250.4130.533.67060.22
25TFU503M251.5151119.51626.21.251.60.41.237.541.381.590.35
32TFU504M321.5151726.521.533.91.620.41.24650.690110.54
40TFU505M401.51522322840.41.620.41.65560.593150.76
50TFU506M501.51529.5443853.222.50.61.67077101.5211.2
63TFU507M631.51541.555526622.50.61.68088113251.49
75TFU508M751.51553.56864.578.52.53.150.61.6100110112.5302.61
90TFU509M902246678.57590.53.1540.81.6114125.4150.5324.91
100TFU5010M1002247690.586101.53.1540.81.6123135.3160.5335.22
115TFU5011M1152248698101110.53.1540.81.6133146.3180.5347.25
130TFU5012M13022497.5115110123.53.1540.81.6153168.3191.5359.47
Dimensions listed are for cable glands with metric equipment entry threads only. Alternative entry thread types e.g. NPT are available; dimensions may vary.
Part numbers listed are for nickel plated brass cable glands only. Alternative materials are available. ‡ Also available in M16 on request
For material options, please change the ‘material suffix’, which is the first digit in the ‘ordering suffix’. Brass = 0, Stainless Steel = 4 and Nickel Plated Brass = 5.
Examples: 20TFU002 = Brass M20, 40TFU405 = Stainless Steel M40
For NPT thread options, please change the second digit in the ‘ordering suffix’ to 3 (denotes NPT) and change the final digit to denote the thread size i.e. ½” = 31, ¾” = 32, 1” = 33, 1-1/4” = 34,
1-1/2” = 35, 2” = 36, 2-1/2” = 37, 3” = 38, 3-1-2” = 39, 4” = 310, 5” = 312. Examples: 32TFU533 = Nickel Plated Brass 1” NPT, 50TFU436 = Stainless Steel 2” NPT
Sizes 90-130 are provided with a reversible armour cone. The ‘X’ side clamps 0.8 – 1.6 mm and the ‘W’ side clamps 3.15 – 4.0 mm

Technical Illustration

Additional Information

DIN 40050 Definitions

The following page provides an explanation of ingress protection codes according to DIN 40050-9 (liquids) and IEC 60529 (dusts).

Read more

Electrical Safety in the Work Place

Local codes of practice or regulations may be in force to ensure that safety is maintained to eliminate the possibility of accidents arising from the danger of electricity. These dangers would include electric shock, burns, fire, explosion and arcing. In the United Kingdom the ESQCR 2002, and amendments 2006 (S.I. No. 1521) and 2009 (S.I. No. 639), introduced under Statutory Instrument No. 2665, and the Electricity at Work Regulations 1989 (EAW Regulations), which came into force on 1 April 1990, comprehensively deal with this subject.

Read more

EMC Performance

Tests were carried out in an anechoic chamber using various CMP cable glands with a section of cable connected to it which would act as an aerial. A known electrical radiation source was used to introduce interference into the chamber, and the level of radiation in the cable shield was measured.

Read more

Visit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.

Log in now