Double Seal, Globally Approved, Explosive Atmosphere Barrier Cable Gland
• Direct & remote installation
• Superior levels of cable retention
• Displacement type environmental seal
• Compound barrier type flameproof seal
• Designed to prevent Coldflow
• Deluge protected
• -60˚C to +85˚C
• Class I Zone 1, 21 and Zone 2, 22
• Globally marked, IECEx, ATEX, UL & cCSAus
| BS 6121:Part 1:1989, IEC 62444, EN 62444 | |
| Impact = Level 8, Retention = Class B | |
| IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only | |
| CML 18ATEX1325X, CML 18ATEX4317X | |
| II 2 GD, II 1D, Ex d IIC Gb, Ex e IIc Gb, Ex ta IIIC Da II 3 G Ex nR IIC Gc, IM2 Ex d I Mb, Ex e I Mb |
|
| EN 60079-0,1,7,15,31 | |
| IECEx CML 18.0182X, IECEx SIM 14.0008X | |
| Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex d I Mb, Ex e I Mb | |
| IEC 60079-0,1,7,15,31 | |
| 2288626 | |
| Class I, Div. 1, 2 Groups A, B, C and D; Class II, Div. 1, 2 Groups E, F and G; Class III, Div. 1, 2; Type 4X: Oil Resistant II: Class I, Zone 1 AEx d IIC Gb, AEx e IIC Gb, Class I, Zone 2 AEx nR IIC Gc, Class I, Zone 20 AEx ta IIIC Da |
|
| Class I, Div. 1, 2 Groups A, B, C and D; Class II, Div. 1, 2 Groups E, F and G; Class III, Div. 1, 2; Type 4X: Oil Resistant II: Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da |
|
| CAN/CSA-C22.2 No 0,18,25,30,174,94, CAN/CSA-E60079-0,1,7,15,31, CAN/ CSA-E61241-1-1 Part 1-1, ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079 |
|
| E201187B, E253914 | |
| Class I, Groups A,B,C,D, Class II, Groups F,G Class I, Zone 1, AEx d IIC, AEx e II |
|
| UL 2225, CSA C22.2 No 174 UL 2225, UL 514B, UL 60079-0, UL 60079-7 |
|
| TC RU C-GB.ГБ05.B00138 | |
| UA.TR.047.C.0644-15 | |
| 14-GA4BO-0252X | |
| P444949 | |
| GYJ13.1140X, GYJ13.1282X | |
| TÜV 12.2073X | |
| 03866 | |
| LRS: 01/00172 (E3), DNV: E-13848, ABS: 14-LD234401A-4-PDA | |
| IP66, IP67 & IP68 | |
| DTS01 : 91 | |
| Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium | |
| CMP SOLO LSF Halogen Free Thermoset Elastomer / Epoxy Barrier Compound | |
| Unarmoured*** | |
| CMP Unique Displacement Seal Concept | |
| Inner Compound Barrier & Outer Sheath |
Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings
***Where the cable is permitted by code (NEC and/or CEC)