EN RU CN

Product Finder

Our Product Finder tool allows you to find the perfect product for your requirements.

оронавирус COVID–19: Информация для клиентов касательно коронавируса COVID-19

PX2KX | Ex e, Ex d, Ex nR & Ex ta | Explosive Atmosphere Barrier Cable GlandFor all types of Braid & Tape Armoured Cables

Globally Approved, Explosive Atmosphere Barrier Cable Gland 

• Metal-to-metal armour clamping
• Direct & remote installation
• Compound barrier type flameproof seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Integral protected deluge seal
• -60˚C to +85˚C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 1 & 2 ABCD
• Globally marked, IECEx, ATEX, UL & cCSAus
• EMC tested

† Grooved Cone (X) is predominantly used for Wire Braid (e.g. GSWB, TCWB), Steel Tape Armour (STA, DSTA) and Aluminium Strip Armour (ASA) but is also suitable for Single Wire Armour (SWA), Aluminium Wire Armour (AWA) and Pliable Wire Armour (PWA) if the range is outside that of the Stepped Cone (W).

Note: Grooved Cone (X) dimensions shown in the Cable Gland Selection Table below are for a double wire strand of braid armour cables. Tapes can also be doubled over. For cables that have only a single layer of armour such as SWA the clamping range should be used as shown in the table below.

BS 6121:Part 1:1989, IEC 62444, EN 62444
Impact = Level 8, Retention = Class B
IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Category B (Category A when used with braid, tape or pliable wire armour cables)
CML 18ATEX1325X, CML 18ATEX4317X
II 2G, II 1D, Ex d IIC Gb, Ex e IIC Gb, Ex ta IIIC Da,
II 3G Ex nR IIC Gc, IM2 Ex d I Mb, Ex e I Mb
EN 60079-0,1,7,15,31
IECEx CML 18.0182X, IECEx SIM 14.0008X
Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex d I Mb, Ex e I Mb
IEC 60079-0,1,7,15,31
2288626
Class I, Div. 1, 2 Groups A, B, C and D; Class II, Div. 1, 2 Groups E, F and G; Class III, Div. 1, 2; Type
4X: Oil Resistant II:
Class I, Zone 1 AEx d IIC Gb, AEx e IIC Gb, Class I, Zone 2 AEx nR IIC Gc,
Class I, Zone 20 AEx ta IIIC Da
Class I, Div. 1, 2 Groups A, B, C and D; Class II, Div. 1, 2 Groups E, F and G; Class III, Div. 1, 2; Type
4X: Oil Resistant II:
Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da
Class I, Div 1,2, Groups A,B,C,D; Class II, Div 1,2, Groups E,F,G, Class III, Div 1,2; Class I Zone 1, AEx d IIC, AEx nR II, NEMA 4X , Oil Resistant II
AEx d IIC Gb, AEx e IIC Gb, Class I, Zone 2 AEx nR IIC Gc, Class I, Zone 20 AEx ta IIIC Da
CAN/CSA-C22.2 No 0,18,25,30,94,174, CAN/CSA-E60079-0,1,7,15,31 CAN/CSA-E61241-1-1 Part
1-1, ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079
E201187, E161256C
Class I Div 1,2, Groups A,B,C,D, Class II Div 1,2, Groups E,F,G
UL 2225, CSA C22.2 No 174, UK 514B, CSA C22.2 No 18, CSA C22.2 No 30
TC RU C-GB.ГБ05.B00138
UA.TR.047.C.0644-15
14-GA4BO-0252X
P444949
GYJ13.1140X, GYJ13.1282X
TÜV 12.2073X
03866
LRS: 01/00172 (E3), DNV: E-13848, ABS: 14-LD234401A-4-PDA
IP66, IP67 & IP68
DTS01 : 91
Electroless Nickel Plated Brass, Brass,   Stainless Steel, Aluminium
CMP SOLO LSF Halogen Free Thermoset Elastomer / Epoxy Barrier Compound
Screened Flexible (EMC) Wire Braid (e.g. CY / SY), Pliable Wire Armour (PWA), Steel Tape
Armour (STA), Wire Braid Armour (e.g. SWB), Aluminium Strip Armour (ASA), Armoured
& Jacketed***
Detachable Compound Tube / Cone & AnyWay Universal Clamping Ring
Unique CMP ‘LRS’ Outer Seal (Load Retention Seal)
Inner Compound Barrier & Outer Sheath

Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings
***Where the cable is permitted by code (NEC and/or CEC)

Certificates

Click here to view Certificates

Product Selection Table

Click here to view Technical Illustration

Technical Illustration

Click here to view how to order

Cable Gland SizeAvailable Entry Threads “"C”" (Alternate Metric Thread Lengths Available)Number of CoresDiameter Over Conductors
"“A"”
Cable
Bedding
Diameter
"“G"”
Overall
Cable
Diameter
“"B”"
Armour Range †
Grooved Cone (X)
Across
Flats
“"D”"
Across
Corners
"“D”"
Protrusion
Length “"F”"
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Ozs)
StandardOption
MetricThread Length (Metric) “"E"”NPTThread Length
(NPT) “"E”"
NPTMaxMaxMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20s16M200.5911/2”"0.7833/4”"210.4610.4610.240.5160.0120.0391.2011.3232.44120S16PX2KX1RAPVC068.466
20SM200.5911/2”"0.7833/4”"210.4610.4610.3740.6260.0120.0391.2011.3232.44120SPX2KX1RAPVC068.113
20M200.5911/2”"0.7833/4”"210.4960.5080.4920.8230.0160.0391.2011.3232.4820PX2KX1RAPVC068.466
25SM250.5913/4”"0.7951”"300.6890.7050.5510.8660.0160.0471.4761.6262.73625SPX2KX1RAPVC0913.051
25M250.5913/4”"0.7951”"300.6890.7050.7171.0310.0160.0471.4761.6262.73625PX2KX1RAPVC0913.051
32M320.5911”"0.9841 1/4”"500.9290.9410.9331.3350.0160.0471.8111.9922.95332PX2KX1RAPVC1120.106
40M400.5911 1/4”"1.0081 1/2”"591.1811.1931.0981.5910.0160.0632.1652.3822.95340PX2KX1RAPVC1528.219
50SM500.5911 1/2”"1.0282”"891.4411.4531.3861.8390.0160.0632.3622.5983.03150SPX2KX1RAPVC1831.747
50M500.5912”"1.0592 1/2”"1151.6141.6261.5912.0870.0240.0632.7563.0313.03150PX2KX1RAPVC2141.976
63SM630.5912”"1.0592 1/2”"1151.8861.9061.7952.3390.0240.0632.9533.2483.13863SPX2KX1RAPVC2349.031
63M630.5912 1/2”"1.5713”"1152.1142.1262.152.5910.0240.0633.153.4653.16163PX2KX1RAPVC2549.736
75SM750.5912 1/2”"1.5713”"1402.3582.372.3232.8350.0240.0633.5433.8983.41775SPX2KX1RAPVC2873.723
75M750.5913”"1.6343 1/2”"1402.5282.5282.6263.0870.0240.0633.9374.3313.47675PX2KX1RAPVC3089.596
90M900.9453 1/2”"1.6854”"1402.9652.97633.5550.0310.0634.5284.984.0290PX2KX1RAPVC32130.867
100M1000.9453 1/2”"1.6854”"2003.373.3823.393.9920.0310.06355.54.488100PX2KX1RALSF33152.031
Dimensions are displayed in inches unless otherwise stated
Cable Gland SizeAvailable Entry Threads “"C"” (Alternate Metric Thread Lengths Available)Number of CoresDiameter Over Conductors
“"A"”
Cable
Bedding
Diameter
"“G"”
Overall
Cable
Diameter
“"B”"
Armour Range †
Grooved Cone (X)
Across
Flats
"“D”"
Across
Corners
"“D”"
Protrusion
Length “"F”"
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Kgs)
StandardOption
MetricThread Length (Metric) “"E”"NPTThread Length
(NPT) “"E"”
NPTMaxMaxMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20s16M2015.01/2”"19.93/4”"2111.711.76.113.10.31.030.533.662.020S16PX2KX1RAPVC060.24
20SM2015.01/2”"19.93/4”"2111.711.79.515.90.31.030.533.662.020SPX2KX1RAPVC060.23
20M2015.01/2”"19.93/4”"2112.612.912.520.90.41.030.533.663.020PX2KX1RAPVC060.24
25SM2515.03/4”"20.21”"3017.517.914.022.00.41.237.541.369.525SPX2KX1RAPVC090.37
25M2515.03/4”"20.21”"3017.517.918.226.20.41.237.541.369.525PX2KX1RAPVC090.37
32M3215.01”"25.01 1/4”"5023.623.923.733.90.41.246.050.675.032PX2KX1RAPVC110.57
40M4015.01 1/4”"25.61 1/2”"5930.030.327.940.40.41.655.060.575.040PX2KX1RAPVC150.80
50SM5015.01 1/2”"26.12”"8936.636.935.246.70.41.660.066.077.050SPX2KX1RAPVC180.90
50M5015.02”"26.92 1/2”"11541.041.340.453.00.61.670.077.077.050PX2KX1RAPVC211.19
63SM6315.02”"26.92 1/2”"11547.948.445.659.40.61.675.082.579.763SPX2KX1RAPVC231.39
63M6315.02 1/2”"39.93”"11553.754.054.665.80.61.680.088.080.363PX2KX1RAPVC251.41
75SM7515.02 1/2”"39.93”"14059.960.259.072.00.61.690.099.086.875SPX2KX1RAPVC282.09
75M7515.03”"41.53 1/2”"14064.264.266.778.40.61.6100.0110.088.375PX2KX1RAPVC302.54
90M9024.03 1/2”"42.84”"14075.375.676.290.30.81.6115.0126.5102.190PX2KX1RAPVC323.71
100M10024.03 1/2”"42.84”"20085.685.986.1101.40.81.6127.0139.7114.0100PX2KX1RALSF334.31
Dimensions are displayed in millimetres unless otherwise stated