E2FX | Ex e, Ex d, Ex nR, Ex ta | Explosive Atmosphere Cable GlandFor Lead Sheathed Braided & Steel Tape Armoured cables

Internationally Approved, Explosive Atmosphere Cable Gland

• Effectively earths / grounds lead sheathed cables
• Metal-to-metal armour clamping
• Direct & remote installation
• Displacement type flameproof inner seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Designed to prevent Coldflow
• -60˚C to +130˚C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 2 ABCD
• Globally marked, IECEx, ATEX & cCSAus
• EMC tested

Note: † Grooved Cone (X) is predominantly used for Wire Braid (e.g. GSWB, TCWB), Steel Tape Armour (STA, DSTA) and Aluminium Strip Armour (ASA) but is also suitable for Single Wire Armour (SWA),
Aluminium Wire Armour (AWA) and Pliable Wire Armour (PWA) if the range is outside that of the Stepped Cone (W).

Note: Grooved Cone (X) dimensions shown in the Cable Gland Selection Table below are for a double wire strand of braid armour cables. Tapes can also be doubled over. For cables that have only a
single layer of armour such as SWA the clamping range should be used as shown in the table below.

BS 6121:Part 1:1989, IEC 62444, EN 62444
Impact = Level 8, Retention = Class B
IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Category B (Category A when used with braid, tape or pliable wire armour cables)
CML 18ATEX1324X, CML 18ATEX4316X
II 2G, II 1D, Ex d IIC Gb, Ex e IIC Gb, Ex ta IIIC Da
II 3G Ex nR IIC Gc, IM2 Ex d I Mb, Ex e I Mb
EN 60079-0,1,7,15,31
IECEx CML 18.0181X, IECEx SIM 14.0007X
Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex d I Mb, Ex e I Mb
IEC 60079-0,1,7,15,31
1310517
Ex d IIC; Ex e II; Ex nR II; Class I, Div 2, Groups A,B,C,D, Class II, Div 2 Groups E,F,G,
Class III; Encl Type 4X Class I, Zone 1, AEx e II / AEx nR II
CAN/CSA-C22.2 No 0,18,25,30,174,94, CAN/CSA-E60079-0,1,7,15
ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079-0,1,7,15
TC RU C-GB.ГБ05.B00138
14-GA4BO-0257X
P444949
GYJ13.1140X , GYJ13.1282X
TÜV 12.0618X
03866
LRS: 01/00172 (E3), DNV: E-13848, ABS: 14-LD234401A-4-PDA
IP66 as standard (IP67, IP68 available upon request)
DTS01:91 option available on request (white ferrule for identification purposes)
Brass, Electroless Nickel Plated Brass, Aluminium
CMP SOLO LSF Halogen Free Thermoset Elastomer
Lead Sheathed & Wire Braid Armour (LC/SWB), Lead Sheathed & Pliable Wire Armour
(LC/PWA), Lead Sheathed & Steel Tape Armour (LC/STA), Lead Sheathed & Strip Armour
(LC/ASA)
Detachable Armour Cone & AnyWay Universal Clamping Ring
CMP Inner Displacement Seal & Unique CMP ‘LRS’ ™ Outer Load Retention Seal
Cable Inner Bedding & Outer Cable Sheath

Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings