TMC2 Cable Connector


Electoless Nickel Plated Brass

Click thumbnails for alternate materials

logos

TMC2 Ordinary, Wet & Hazardous Location Cable Connector


CMP Type TMC2 Cable Connector suitable for use with Interlocked & Continuously Welded Metal Clad (Type MC or MC-HL) or TECK armored & jacketed cables in ordinary, wet & hazardous locations including:

  • Certified to CSA, UL, ATEX (EN) & IECEx Standards
  • Class I Division 2, where permitted by code
  • Class 1 Zone 1 AEx e and Ex e, where permitted by code
  • Ingress Protection to Nema 4X and IP68

All CMP Cable Connectors are EMC Tested.

Click for more details

The 2-part design allows the grounding and over jacket sealing to be actioned in a single simple movement and allows he cable to be easily removed from the equipment, for maintenance and change out etc.

The TMC2 cable connector is supplied in Copper free (<0.4%), Aluminium, Stainless Steel, or Electroless Nickel Plated Brass in NPT (standard) and Metric thread forms.

Cable Gland Selection Table

  • View Metric Table
  • View Imperial Table
Order Reference (NPT) Entry Thread "C" Minimum Thread Length "E" Cable Armor Diameter "A" Cable Jacket Diameter "B" Across Flats "D" Across Corners "D" Nominal Assembly Length "F" Approx Weight Aluminum (Kgs)
Aluminum Nickel Plated Brass Stainless Steel NPT NPT Option
Min Max Min Max
TMC2-050A075 TMC2-050NB075 TMC2-050SS075 1/2" - 19.81 10.67 16.00 12.70 19.05 30.48 33.02 41.91 0.06
TMC2-075A075 TMC2-075NB075 TMC2-075SS075 - 3/4" 20.32
TMC2-050A099 TMC2-050NB099 TMC2-050SS099 1/2" - 19.81 15.24 22.61 17.53 25.15 37.59 40.64 50.04 0.09
TMC2-075A099 TMC2-075NB099 TMC2-075SS099 - 3/4" 20.32
TMC2-075A118 TMC2-075NB118 TMC2-075SS118 3/4" - 20.07 20.07 27.94 22.10 29.97 45.97 49.53 54.10 0.14
TMC2-100A118 TMC2-100NB118 TMC2-100SS118 - 1" 24.89
TMC2-100A137 TMC2-100NB137 TMC2-100SS137 1" - 24.89 23.88 32.51 25.91 34.80 52.07 56.13 59.44 0.19
TMC2-125A137 TMC2-125NB137 TMC2-125SS137 - 1-1/4" 25.40
TMC2-125A162 TMC2-125NB162 TMC2-125SS162 1-1/4" - 25.40 30.99 38.10 33.02 41.15 59.94 64.77 61.98 0.25
TMC2-150A162 TMC2-150NB162 TMC2-150SS162 - 1-1/2" 26.92
TMC2-125A190 TMC2-125NB190 TMC2-125SS190 1-1/4" - 26.16 37.85 43.69 39.88 48.26 65.02 70.10 61.98 0.27
TMC2-150A190 TMC2-150NB190 TMC2-150SS190 - 1-1/2" 26.92
TMC2-150A200 TMC2-150NB200 TMC2-150SS200 1-1/2" - 26.92 39.88 47.75 41.91 50.80 69.85 75.44 66.04 0.31
TMC2-200A200 TMC2-200NB200 TMC2-200SS200 - 2" 39.88
TMC2-150A233 TMC2-150NB233 TMC2-150SS233 1-1/2" - 26.92 45.47 56.13 48.51 59.18 74.93 81.03 67.06 0.36
TMC2-200A233 TMC2-200NB233 TMC2-200SS233 - 2" 39.88
TMC2-200A272 TMC2-200NB272 TMC2-200SS272 2" - 39.88 54.36 66.29 57.66 69.09 89.92 97.03 70.10 0.70
TMC2-250A272 TMC2-250NB272 TMC2-250SS272 - 2-1/2" 39.88
TMC2-300A325 TMC2-300NB325 TMC2-300SS325 3" - 41.40 63.25 75.44 66.55 82.55 109.98 118.87 87.88 1.21
TMC2-350A325 TMC2-350NB325 TMC2-350SS325 - 3-1/2" 42.67
TMC2-350A376 TMC2-350NB376 TMC2-350SS376 3-1/2" - 42.67 74.93 89.92 80.26 95.50 122.94 132.84 93.47 1.51
TMC2-400A376 TMC2-400NB376 TMC2-400SS376 - 4" 43.94
TMC2-400A425 TMC2-400NB425 TMC2-400SS425 4" - 43.94 89.41 100.08 93.98 107.95 132.84 143.51 98.81 1.68
Dimensions are displayed millimeters unless otherwise stated

Order Code Example: TMC2-150-A-200 - "TMC2" (Type Gland) - "150" (1-1/2" NPT Thread) - "A" (Material Aluminum) - "200"(Max Cable Diameter 2")

Order Reference (NPT) Entry Thread "C" Minimum Thread Length "E" Cable Armor Diameter "A" Cable Jacket Diameter "B" Across Flats "D" Across Corners "D" Nominal Assembly Length "F" Approx Weight Aluminum (Ozs)
Aluminum Nickel Plated Brass Stainless Steel NPT NPT Option
Min Max Min Max
TMC2-050A075 TMC2-050NB075 TMC2-050SS075 1/2" - 0.78 0.42 0.63 0.50 0.75 1.20 1.30 1.65 2.29
TMC2-075A075 TMC2-075NB075 TMC2-075SS075 - 3/4" 0.80
TMC2-050A099 TMC2-050NB099 TMC2-050SS099 1/2" - 0.78 0.60 0.89 0.69 0.99 1.48 1.60 1.97 3.00
TMC2-075A099 TMC2-075NB099 TMC2-075SS099 - 3/4" 0.80
TMC2-075A118 TMC2-075NB118 TMC2-075SS118 3/4" - 0.79 0.79 1.10 0.87 1.18 1.81 1.95 2.13 5.11
TMC2-100A118 TMC2-100NB118 TMC2-100SS118 - 1" 0.98
TMC2-100A137 TMC2-100NB137 TMC2-100SS137 1" - 0.98 0.94 1.28 1.02 1.37 2.05 2.21 2.34 6.70
TMC2-125A137 TMC2-125NB137 TMC2-125SS137 - 1-1/4" 1.00
TMC2-125A162 TMC2-125NB162 TMC2-125SS162 1-1/4" - 1.00 1.22 1.50 1.30 1.62 2.36 2.55 2.44 8.82
TMC2-150A162 TMC2-150NB162 TMC2-150SS162 - 1-1/2" 1.06
TMC2-125A190 TMC2-125NB190 TMC2-125SS190 1-1/4" - 1.03 1.49 1.72 1.57 1.90 2.56 2.76 2.44 9.45
TMC2-150A190 TMC2-150NB190 TMC2-150SS190 - 1-1/2" 1.06
TMC2-150A200 TMC2-150NB200 TMC2-150SS200 1-1/2" - 1.06 1.57 1.88 1.65 2.00 2.75 2.97 2.60 11.06
TMC2-200A200 TMC2-200NB200 TMC2-200SS200 - 2" 1.57
TMC2-150A233 TMC2-150NB233 TMC2-150SS233 1-1/2" - 1.06 1.79 2.21 1.91 2.33 2.95 3.19 2.64 12.77
TMC2-200A233 TMC2-200NB233 TMC2-200SS233 - 2" 1.57
TMC2-200A272 TMC2-200NB272 TMC2-200SS272 2" - 1.57 2.14 2.61 2.27 2.72 3.54 3.82 2.76 24.69
TMC2-250A272 TMC2-250NB272 TMC2-250SS272 - 2-1/2" 1.57
TMC2-300A325 TMC2-300NB325 TMC2-300SS325 3" - 1.63 2.49 2.97 2.62 3.25 4.33 4.68 3.46 42.68
TMC2-350A325 TMC2-350NB325 TMC2-350SS325 - 3-1/2" 1.68
TMC2-350A376 TMC2-350NB376 TMC2-350SS376 3-1/2" - 1.68 2.95 3.54 3.16 3.76 4.84 5.23 3.68 53.44
TMC2-400A376 TMC2-400NB376 TMC2-400SS376 - 4" 1.73
TMC2-400A425 TMC2-400NB425 TMC2-400SS425 4" - 1.73 3.52 3.94 3.70 4.25 5.23 5.65 3.89 59.19
Dimensions are displayed inches unless otherwise stated

Order Code Example: TMC2-050A028 - "TMC"" (Type Gland) - "050" (1/2" NPT Thread) - "A" (Material Aluminum) - "028"(Max Cable Diameter 0.28")

TECHNICAL DATA
GOST R Certificate Number POCC GB.HO06.B00207
GOST R Code of Protection Category Ex d IIC X / Ex e II X / DIP A21
GOST R Compliance Standards ГOCT P 52350.0-2005, ГOCT P 52350.1-2005,
ГOCT P 52350.7-2005, ГOCT MЭK 61241-1-1-99
GOST GGTN Permit PPC 00-40706
DNV Approval No. E-10496
ABS Approval No. 10-HS630287
GOST K Certificate Number KZ 75000361 01 01 14761
RoK Permit For Use Number 19-02-UL-1957
cCSAus Approval Certificate No. CSA.09.2194053
sCSAus Code of Protection Category Class I Div 2 Groups ABCD, Class II Div 2 EFG, Class III, Class 1 Zone 2, AEx e II, Ex e, Ordinary & Wet Locations
cCSAus Compliance Standards CAN/CSA-C22.2 No 0-M91, CAN/CSA-C22.2 No 18-04, CAN/CSA-C22.2 No 25-1966, CAN/CSA-C22.2 No 30-M1986, CAN/CSA-C22.2 No.174-M1984, CAN/CSA-C22.2 No.94-M91, CAN/CSA-E60079-0:07, CAN/CSA-E60079-7:07, CAN/CSA-E60079-1:07, CAN/CSA-E61241-1-1, ANSI/UL 514B Edition 5, ANSI/UL 50 Edition 11, ANSI/UL 2225 Edition 4
RETIE Approval Number 03866
Type TMC2
Design Specification BS 6121:Part 1:1999, UL 514B, UL 2225, CSA 22.2
ATEX Certification Detail SIRA09ATEX1164X
ATEX Code of Protection Category ATEX ATEX Approved II 2 GD, Ex e IIC Gb, Ex ta IIIC Da
ATEX Compliance Standards EN 60079-0, EN 60079-7, EN 61241-1
IEC Ex Certification Detail IECEx SIR 09.0068X
IEC Ex Code of Protection Category Ex e IIC Gb, Ex ta IIIC Da
IEC Ex Compliance Standards IEC 60079-0, IEC 60079-7, IEC 61241-1
Continuous Operating Temperature -60°C to +110°C
Ingress Protection Rating Nema 4X and IP68
Cable Type Corrugated & Interlocked Metal Clad Armor (MC) or TECK,
Continuously Welded Metal Clad Armor (MCHL)
Armor Clamping 360° Stainless Steel Grounding Spring
Jacket Sealing Technique CMP Load Retention Seal
Sealing Area(s) Cable Outer Jacket
Cable Connector Material Copper Free (<0.4%) Aluminum, Stainless Steel, or Electroless Nickel Plated Brass,
Optional Accessories Adaptor/Reducer, Earth Tag


Additional information

Close [-]

Video Coming Soon

CMP WP TMC2_0311