Product Finder

Product Finder

Our Product Finder tool allows you to find the perfect product for your requirements.

Triton CDS (T3CDS) | Ex e, Ex d, Ex nR & Ex ta | Explosive Atmosphere Cable GlandFor all types of Armoured Cables

Globally Approved, Explosive Atmosphere Cable Gland

• Fully sequential, three step installation procedure
• Reduces installation times, cost & risk
• Direct & remote installation
• Unique compensating displacement seal system (CDS)
– Metal-to-metal installation every time regardless of cable diameter
• Designed to prevent Coldflow
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60˚C to +130˚C (standard), -20˚C to 200˚C (ThermEx option T3CDSHT)
• Globally marked, IECEx, ATEX, UL & cCSAus
• EMC tested

† Grooved Cone (X) is predominantly used for Wire Braid (e.g. GSWB, TCWB), Steel Tape Armour (STA, DSTA) and Aluminium Strip Armour (ASA) but is also suitable for Single Wire Armour (SWA), Aluminium Wire Armour (AWA) and Pliable Wire Armour (PWA) if the range is outside that of the Stepped Cone (W).

Note: Grooved Cone (X) dimensions shown in the Cable Gland Selection Table below are for a double wire strand of braid armour cables. Tapes can also be doubled over. For cables that have only a single layer of armour such as SWA the clamping range should be used as shown in the table below.

Stepped (W) Cone is suitable for Single Wire Armour (SWA), or Aluminium Wire Armour (AWA) cables.

For under / oversized armour wires click here

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications* Impact = Level 8, Retention = Class D
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications* Category B (Category A when used with braid, tape or pliable wire armour cables)
ATEX Certificate SIRA13ATEX1073X
SIRA13ATEX4079X
Code of Protection II 2G,II 1D, Ex d IIC Gb, Ex e IIC Gb, Ex ta IIIC Da,
II 3G Ex nR IIC Gc, I M2, Ex d I Mb, Ex e I Mb
Compliance Standards EN60079-0,1,7,15,31
IECEx Certificate IECEx SIR 13.0028X
IECEx SIM 14.0007X
Code of Protection Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex d I Mb, Ex e I Mb
Compliance Standards IEC 60079-0,1,7,15,31
cCSAus Certificate (20s16 - 90) 1310517
CSAus Code of Protection Class I, Div 2, Groups A,B,C and D, Class II, Div 2, Groups E,F and G, Class III, Enclosure
Type 3, 4 and 4X,
Class I, Zone 1, AEx e II, AEx nR II
cCSA Code of Protection Class I, Div 2, Groups A,B,C and D, Class II, Div 2, Groups E,F and G, Class III, Enclosure
Type 3, 4 and 4X,
Ex d IIC, Ex e IIC, Ex nR II
Compliance Standards CAN/CSA-C22.2 No 0, 18, 25, 30, 94, 174, CAN/CSA-E60079-0, 1, 7,
ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079-0, 1, 7
UL Certificate (20s16 - 90) E200163
Code of Protection Class I, Zone 1, AEx e II
Compliance Standards UL514B
EAC Certificate (Formerly GOST R, K & B) TC RU C-GB.AA87.B.00487
UkrSEPRO UA.TR.047.C.0644-15
NEPSI Certificate GYJ13.1141X , GYJ13.1283X
CCOE / PESO (India) Certificate P333688
INMETRO Certificate TÜV 11.0374X
RETIE Certificate 03866
Marine Approvals LRS: 01/00172 (E3), DNV: TAE00000Y, ABS: 14-LD234401A-4-PDA, BV: 43180/A1BV
Ingress Protection Rating ** IP66, IP67 & IP68
Deluge Protection Compliance DTS01 : 91
Cable Gland Material Brass, Electroless Nickel Plated Brass, Aluminium, Stainless Steel
Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer
Cable Type Single Wire Armour (SWA), Aluminium Wire Armour (AWA), Pliable Wire Armour (PWA), Steel Tape Armour (STA), Aluminium Strip Armour (ASA), Screened Flexible (EMC) Wire Braid (e.g. CY/SY), Wire Braid Armour (e.g. SWB)
Armour Clamping Reversible Armour Cone & AnyWay Universal Clamping Ring
Sealing Technique Inner Bedding Sealing Ring: Compensating Displacement Seal (CDS), Outer Sheath Sealing Ring : Load Retention Seal (LRS)
Sealing Area(s) Cable Inner Bedding & Outer Cable Sheath
Optional Accessories Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation Tools Spanners, Armour Former Tool

Note: * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
*** IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request

Watch Installation Video Introducing the Sentinel

Certificates

Click here to view Certificates

Product Selection Table

Click here to view Technical Illustration

Technical Illustration

Click here to view how to order

Cable Gland SizeAvailable Entry Threads “C” (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
“A”
Overall
Cable
Diameter
“B”
Armour RangeAcross
Flats
“D”
Across
Corners
“D”
Protrusion
Length “F”
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Ozs)
StandardOptionGrooved Cone (X)Stepped Cone (W)
MetricThread Length (Metric) “E”NPTThread Length
(NPT) “E”
NPTMinMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
16M1615.0---0.120.340.240.520.010.040.030.050.941.043.1016T3CDS1RAPVC366.35
20S16M2015.0½”0.78¾"0.120.340.240.520.010.040.030.050.941.043.1020S16T3CDS1RAPVC367.05
20SM2015.0½”0.78¾"0.240.460.370.630.010.040.030.050.941.043.1020ST3CDS1RAPVC367.05
20M2015.0½”0.78¾"0.260.550.490.820.020.040.030.051.201.323.0020T3CDS1RAPVC069.88
25SM2515.0¾”0.801"0.440.780.550.870.020.050.050.061.481.633.5025ST3CDS1RAPVC0915.52
25M2515.0¾”0.801"0.440.780.721.030.020.050.050.061.481.633.4925T3CDS1RAPVC0915.52
32M3215.00.981 ¼"0.671.030.931.330.020.050.060.081.811.993.5732T3CDS1RAPVC1122.22
40M4015.01 ¼”1.011 ½"0.871.261.101.590.020.060.060.082.172.383.6740T3CDS1RAPVC1532.10
50SM5015.01 ½”1.032"1.161.501.391.840.020.060.080.102.362.603.9650ST3CDS1RAPVC1839.51
50M5015.01.062 ½"1.401.731.592.090.020.060.080.102.763.044.1750T3CDS1RAPVC2156.44
63SM6315.01.062 ½"1.581.961.802.340.020.060.080.102.953.254.0463ST3CDS1RAPVC2361.02
63M6315.02 ½”1.573"1.862.202.152.590.020.060.080.103.153.464.1563T3CDS1RAPVC2562.79
75SM7515.02 ½”1.573"2.082.442.322.830.020.060.080.103.543.904.3575ST3CDS1RAPVC2890.65
75M7515.01.633 ½"2.332.672.633.090.020.060.100.123.944.334.7475T3CDS1RAPVC30117.46
90M9024.03 ½”1.694"2.623.093.003.560.030.060.120.164.534.985.4790T3CDS1RAPVC32171.78
100M10024.03 ½”1.694"2.993.583.393.990.030.060.120.165.005.505.05100T3CDS1RALSF33175.31
115M11524.04"1.735"3.393.854.004.340.030.060.120.165.435.986.35115T3CDS1RALSF34272.32
130M13024.05"1.84-3.824.524.344.850.030.060.120.166.186.806.82130T3CDS1RALSF35344.98
Dimensions displayed in inches unless otherwise stated
Cable Gland SizeAvailable Entry Threads “C” (Alternate Metric Thread Lengths Available)Cable
Bedding
Diameter
“A”
Overall
Cable
Diameter
“B”
Armour RangeAcross
Flats
“D”
Across
Corners
“D”
Protrusion
Length “F”
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Kgs)
StandardOptionGrooved Cone (X)Stepped Cone (W)
MetricThread Length (Metric) “E”NPTThread Length
(NPT) “E”
NPTMinMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
16M1615.0---3.18.66.113.10.31.00.81.324.026.478.716T3CDS1RAPVC360.18
20S16M2015.0½”19.9¾"3.18.66.113.10.31.00.81.324.026.478.720S16T3CDS1RAPVC360.20
20SM2015.0½”19.9¾"6.111.69.515.90.31.00.81.324.026.478.720ST3CDS1RAPVC360.20
20M2015.0½”19.9¾"6.513.912.520.90.41.00.81.330.533.676.220T3CDS1RAPVC060.28
25SM2515.0¾”20.21"11.119.914.022.00.41.21.31.637.541.388.825ST3CDS1RAPVC090.44
25M2515.0¾”20.21"11.119.918.226.20.41.21.31.637.541.388.725T3CDS1RAPVC090.44
32M3215.025.01 ¼"17.026.223.733.90.41.21.62.046.050.690.732T3CDS1RAPVC110.63
40M4015.01 ¼”25.61 ½"22.032.127.940.40.41.61.62.055.060.593.240T3CDS1RAPVC150.91
50SM5015.01 ½”26.12"29.538.135.246.70.41.62.02.560.066.0100.750ST3CDS1RAPVC181.12
50M5015.026.92 ½"35.644.040.453.00.61.62.02.570.177.1105.850T3CDS1RAPVC211.60
63SM6315.026.92 ½"40.149.945.659.40.61.62.02.575.082.5102.563ST3CDS1RAPVC231.73
63M6315.02 ½”39.93"47.255.954.665.80.61.62.02.580.088.0105.463T3CDS1RAPVC251.78
75SM7515.02 ½”39.93"52.861.959.072.00.61.62.02.590.099.0110.675ST3CDS1RAPVC282.57
75M7515.041.53 ½"59.167.966.778.40.61.62.53.0100.0110.0120.375T3CDS1RAPVC303.33
90M9024.03 ½”42.84"66.678.676.290.30.81.63.24.0115.0126.5138.990T3CDS1RAPVC324.87
100M10024.03 ½”42.84"76.090.986.1101.40.81.63.24.0127.0139.7128.2100T3CDS1RALSF334.97
115M11524.04"44.05"86.097.9101.5110.20.81.63.24.0138.0151.8161.3115T3CDS1RALSF347.72
130M13024.05"46.8-97.0114.9110.2123.20.81.63.24.0157.0172.7173.3130T3CDS1RALSF359.78
Dimensions displayed in millimeters unless otherwise stated

Newsletter